2025-11-13T01:46:10.842403

Certifying non-classicality and non-Gaussianity through optical parametric amplification

Kalash, Passos, Rácz et al.
Non-Gaussian states of light are essential for numerous quantum information protocols; thus, certifying non-Gaussianity is crucial. Full quantum state tomography, commonly used for this purpose, is a complicated procedure and yields inconclusive results for strongly mixed states. Certifying non-Gaussianity through directly measurable parameters is a simpler alternative, typically achieved by measuring photon-number probabilities - either directly, using photon-number resolving detectors, or through Hanbury Brown--Twiss type measurements with single-photon detectors. Here, we demonstrate theoretically and experimentally that optical parametric amplification combined with conventional intensity detectors can effectively replace this approach without the need for photon-number resolution. In our method, we measure the mean photon number and the second-order correlation function for the amplified state. Using it, we successfully certify the non-Gaussianity of a heralded quasi-single-photon state. Since optical parametric amplification is a broadband and multimode process, our method provides a foundation for developing high-dimensional quantum technologies utilizing broadband multimode non-Gaussian states.
academic

Certifying non-classicality and non-Gaussianity through optical parametric amplification

基本信息

  • 论文ID: 2507.18296
  • 标题: Certifying non-classicality and non-Gaussianity through optical parametric amplification
  • 作者: Mahmoud Kalash, M.H.M. Passos, Éva Rácz, László Ruppert, Radim Filip, Maria V. Chekhova
  • 分类: quant-ph (量子物理)
  • 发表时间: 2025年10月13日编译
  • 论文链接: https://arxiv.org/abs/2507.18296

摘要

非高斯光态对于众多量子信息协议至关重要,因此认证非高斯性是关键问题。传统的全量子态层析成像虽然常用于此目的,但过程复杂且对强混合态产生不确定结果。通过直接可测参数认证非高斯性是一种更简单的替代方案,通常通过测量光子数概率实现——要么使用光子数分辨探测器直接测量,要么通过单光子探测器的Hanbury Brown-Twiss型测量。本文理论和实验证明,光学参量放大结合传统强度探测器可以有效替代这种方法,无需光子数分辨。该方法通过测量放大态的平均光子数和二阶相关函数,成功认证了预报准单光子态的非高斯性。由于光学参量放大是宽带多模过程,该方法为开发利用宽带多模非高斯态的高维量子技术提供了基础。

研究背景与动机

问题定义

量子光学中存在三个层次的量子态分类:

  1. 经典态:可表示为相干态混合的光态
  2. 非经典态:不能表示为相干态混合但仍可能是高斯态
  3. 非高斯态:不能表示为高斯Wigner函数态的混合

重要性

非高斯光态在量子信息协议中不可或缺,特别是:

  • 纠缠蒸馏
  • 量子纠错
  • 高维量子技术

现有方法局限性

  1. 全量子态层析成像:过程复杂,对强混合态结果不确定
  2. Wigner函数负性检测:对混合非高斯态,Wigner函数可能为正
  3. 光子数概率测量:需要光子数分辨探测器或多个单光子探测器
  4. Hanbury Brown-Twiss测量:仅适用于平均光子数远小于1的暗态

研究动机

开发一种新方法,能够:

  • 避免复杂的光子数分辨探测
  • 适用于更亮的量子态
  • 利用常规强度探测器
  • 支持宽带多模检测

核心贡献

  1. 提出了基于光学参量放大的新认证方法:通过测量放大后的平均光子数μ和二阶相关函数g^(2)来认证非高斯性和非经典性
  2. 建立了新的见证函数:在(μ_rel, g^(2))参数空间中构建了非高斯性和非经典性的边界条件
  3. 实验验证了方法有效性:成功认证了预报准单光子态的非高斯性,并追踪了从非高斯到非经典再到经典的转变过程
  4. 提供了理论框架:为相位无关态建立了放大前后统计量之间的精确关系
  5. 展示了宽带多模潜力:为高维量子技术应用奠定了基础

方法详解

任务定义

输入:未知量子光态 输出:认证结果(非高斯/非经典/经典或不确定) 约束:适用于相位无关态(Wigner函数仅依赖于x² + p²)

核心原理

光学参量放大变换

使用Bogoliubov变换描述参量放大过程:

â = â₀ cosh G + â₀† sinh G

其中G为参量增益,â₀为输入算符。

关键参数

  1. 相对平均光子数:μ_rel ≡ μ/μ_vac,其中μ_vac = sinh² G为放大真空的平均光子数
  2. 二阶相关函数:g^(2) = ⟨a†a†aa⟩/⟨a†a⟩²

放大前后关系

对于大增益情况(G > 3),建立了精确关系:

μ_rel = 2m + 1
σ²_rel = 2(1 + m + m² + 3s²)

其中m、s²分别为放大前的平均光子数和方差。

见证函数构建

非高斯性见证

通过参数曲线定义边界:

μ̃_rel(r) = e^r cosh 2r
g̃^(2)(r) = 3 - 3·sinh² r·(sinh 2r + 1)/cosh² 2r

当测量结果满足g^(2) < g̃^(2)(μ̃_rel^(-1)(μ_rel))时,可认证非高斯性。

非经典性见证

g^(2) < 3/2 + 3/μ_rel - 3/(2μ²_rel)

实验方案

态制备

  • 使用type-II自发参量下转换(SPDC)产生双光子
  • 通过探测闲频光子预报信号光子
  • 控制泵浦功率调节源亮度

参量放大

  • 使用type-I共线简并相位匹配的BiBO晶体
  • 参量增益G = 6.5 ± 0.5
  • 相敏放大配置

检测系统

  • 使用sCMOS相机进行强度检测
  • 单模光纤确保单模检测
  • 0.5nm带通滤波器保证频谱纯净

实验设置

实验装置

  • 光源:400nm、1ps脉冲,5kHz重复频率
  • SPDC晶体:3mm厚BBO晶体,type-II非共线简并相位匹配
  • OPA晶体:3mm厚BiBO晶体,type-I共线简并相位匹配
  • 探测器:超导纳米线单光子探测器(量子效率80%),sCMOS相机(量子效率50%)

关键参数

  • 预报效率:ηH = 51 ± 2%
  • 放大效率:ηOPA = 51%
  • 总透射率:η = 26%
  • 参量增益:G = 6.5 ± 0.5

评价方法

  1. 标准符合测量:使用HBT装置测量p₀, p₁, p₂₊
  2. 放大后测量:测量μ_rel和g^(2)
  3. 对比验证:将两种方法结果转换到(m, s²)空间进行比较

实验结果

主要结果

非高斯性认证

  • 成功认证了亮度为0.1 ppp的预报态的非高斯性
  • 测得μ_rel = 1.66 ± 0.02,g^(2) = 2.58 ± 0.03
  • 结果位于非高斯区域内(绿色区域)

过渡过程追踪

随着源亮度从0.1增加到0.94 ppp:

  • 0.1-0.15 ppp:非高斯性得到认证
  • 0.39-0.62 ppp:仅能认证非经典性
  • 0.77-0.94 ppp:进入不确定区域

理论符合

实验数据与理论预测(26%有效透射率)高度一致,验证了方法的准确性。

光子数分布分析

  • 放大真空:完全符合理论预测的gamma分布
  • 放大预报态:介于真空和单光子分布之间
  • 不同混合态虽有相似分布但非高斯性质不同

对比验证

将符合测量和放大测量结果都转换到(m, s²)空间,两组数据点高度重合,证明了方法等效性。

相关工作

传统方法

  1. Wigner函数负性:直接但对混合态不适用
  2. 光子宇称检测:需要特殊探测器
  3. 光子数概率方法:Filip-Mišta见证函数,需要光子数分辨

最新进展

  1. 亮态见证:基于平均值和方差的见证函数
  2. 相关函数方法:独立工作中也使用相关函数,但仍需单光子探测器

本文优势

  • 无需光子数分辨探测器
  • 适用于更亮的态
  • 天然支持多模检测
  • 使用常规强度探测器

结论与讨论

主要结论

  1. 方法有效性:光学参量放大结合常规探测器可有效认证非高斯性
  2. 技术优势:避免了复杂的光子数分辨探测需求
  3. 适用范围广:可处理从暗态到亮态的各种情况
  4. 多模潜力:为高维量子技术提供基础

局限性

  1. 相位依赖态:当前方法仅适用于相位无关态
  2. 模式匹配:需要良好的空间和频谱模式匹配
  3. 增益要求:需要足够大的参量增益(G > 3)
  4. 损耗敏感性:虽可校正但仍会影响态纯度

未来方向

  1. 扩展到相位依赖态:需要更复杂的实验装置
  2. 优化模式匹配:提高放大效率
  3. 多模同时检测:实现真正的高维量子技术
  4. 实际应用:在量子信息处理中的具体应用

深度评价

优点

  1. 技术创新性强:首次将OPA用于非高斯性认证,避免了光子数分辨的技术难题
  2. 理论基础扎实:建立了完整的理论框架,包括精确的数学推导
  3. 实验验证充分:不仅验证了方法有效性,还展示了态转变过程
  4. 实用价值高:使用常规探测器,降低了技术门槛
  5. 多模潜力:为高维量子技术开辟新路径

不足

  1. 适用范围限制:仅适用于相位无关态
  2. 模式匹配挑战:实验中OPA效率仅51%,影响性能
  3. 增益依赖性:需要高增益放大器,增加系统复杂性
  4. 对比实验有限:主要与传统HBT方法对比,缺乏与其他新方法的比较

影响力

  1. 学术贡献:为量子态认证提供新思路,可能启发更多相关研究
  2. 技术价值:降低了非高斯性认证的技术门槛,有利于实际应用
  3. 应用前景:为高维量子信息处理提供基础工具
  4. 可复现性:实验方案清晰,参数详细,便于重现

适用场景

  1. 量子光学实验室:作为常规的量子态表征工具
  2. 量子信息处理:在需要认证非高斯资源的协议中
  3. 高维量子技术:多模非高斯态的并行检测
  4. 工业应用:降低成本的量子态质量控制

参考文献

论文引用了32篇重要文献,涵盖了非高斯态理论、见证函数、光学参量放大、量子态层析等相关领域的核心工作,为研究提供了坚实的理论基础。


总体评价:这是一篇高质量的量子光学论文,提出了创新的非高斯性认证方法,理论和实验结合紧密,具有重要的学术价值和实用意义。该工作不仅解决了现有方法的技术限制,还为未来的高维量子技术发展提供了新的工具和思路。