2025-11-14T06:34:14.014526

A Wideband Composite Sequence Impedance Model for Evaluation of Interactions in Unbalanced Power-Electronic-Based Power Systems

Liu, Liu, Han et al.
This paper proposes a wideband composite sequence impedance model (WCSIM)-based analysis method to evaluate the interactions in power-electronic-based power systems subjected to unbalanced grid faults or with unbalanced loads. The WCSIM-based method intuitively assesses the impact of the small-signal interconnection among the positive-, negative-, and zero-sequence circuits on the interaction stability of unbalanced power systems. The effectiveness of this method is demonstrated using a permanent magnet synchronous generator-based weak grid system under a single-line-to-ground fault (SLGF). Frequency scanning results and controller hardware-in-loop tests validate both the correctness of the WCSIM and the effectiveness of the WCSIM-based analysis method.
academic

A Wideband Composite Sequence Impedance Model for Evaluation of Interactions in Unbalanced Power-Electronic-Based Power Systems

基本信息

  • 论文ID: 2510.12914
  • 标题: A Wideband Composite Sequence Impedance Model for Evaluation of Interactions in Unbalanced Power-Electronic-Based Power Systems
  • 作者: Zhi Liu, Chengxi Liu, Jiangbei Han, Rui Qiu, Mingyuan Liu (武汉大学电气工程与自动化学院)
  • 分类: eess.SY cs.SY (电气工程系统与控制、系统与控制)
  • 资助: 国家自然科学基金 (U22B20100)、广东省基础与应用基础研究基金 (2023B1515250001, 2022A1515240033)
  • 论文链接: https://arxiv.org/abs/2510.12914

摘要

本文提出了一种基于宽频复合序阻抗模型(WCSIM)的分析方法,用于评估在不平衡电网故障或不平衡负载条件下电力电子化电力系统的相互作用。WCSIM方法直观地评估了正序、负序和零序电路之间小信号互连对不平衡电力系统相互作用稳定性的影响。通过永磁同步发电机弱电网系统在单相接地故障下的案例验证了该方法的有效性。频率扫描结果和控制器硬件在环测试验证了WCSIM的正确性和基于WCSIM分析方法的有效性。

研究背景与动机

问题描述

随着电力电子设备在电力系统中渗透率的不断提高,系统中的相互作用问题变得更加突出。不稳定的相互作用可能引发振荡,导致设备跳闸甚至系统崩溃。虽然已有多种方法分析和抑制宽频振荡,但这些方法通常局限于平衡系统。

研究重要性

对于遭受不平衡电网故障或具有不平衡负载的电力系统,相互作用变得更加复杂,需要进一步研究。不平衡电网条件可能在正序、负序和零序电路之间引起小信号互连,这可能影响相互作用稳定性。

现有方法局限性

  1. 研究范围局限: 现有研究主要关注平衡系统的宽频振荡分析
  2. 建模不足: 对不平衡电网条件下的风电系统研究主要集中在风机建模,对不平衡电网关注较少
  3. 序分量耦合: 缺乏有效方法评估序分量间小信号互连对系统稳定性的影响

研究动机

传统电力系统在不平衡故障期间使用序互连技术进行稳态分析,这启发了一个重要问题:该技术是否可以应用于评估不平衡电网条件下电力电子化电力系统的宽频相互作用?

核心贡献

  1. 提出WCSIM模型: 首次提出宽频复合序阻抗模型,能够在宽频范围内评估不平衡条件下的系统相互作用
  2. 序分量互连分析: 建立了正序、负序、零序电路间小信号互连的数学模型和分析框架
  3. 等效阻抗推导: 推导出考虑序分量耦合的等效电网阻抗计算公式
  4. 实验验证: 通过频率扫描和控制器硬件在环测试验证了方法的正确性和有效性

方法详解

任务定义

评估电力电子化电力系统在不平衡电网故障(如单相接地故障)或不平衡负载条件下的宽频相互作用稳定性,特别是分析正序、负序、零序电路间小信号互连对系统稳定性的影响。

模型架构

1. 测试系统描述

  • 系统配置: 150台2MW永磁同步发电机风电场通过升压变压器、35kV输电线路和220kV输电线路连接到无穷大电网
  • 变压器配置: 高压侧星形接地,低压侧三角形接线
  • 控制策略: PMSG采用经典矢量控制,PLL中嵌入陷波滤波器抑制负序分量

2. WCSIM推导过程

故障边界条件: 对于A相单相接地故障,小信号相分量边界条件为:

u̇fa(ω) = Rf(s)İfa(ω), İfb(ω) = İfc(ω) = 0

序分量边界条件: 基于对称分量理论,转换为序分量表示:

u̇fpa(ω) + u̇fna(ω) + u̇f0a(ω) = Rf(s)İf(ω)
İfpa(ω) = İfna(ω) = İf0a(ω) = İf(ω)/3

3. 等效阻抗计算

等效正序电网阻抗:

Zgpe(s) = Zg1(s) + [Zg2(s)Zne(s)Rf(s)Z0e(s)] / [Zg2(s) + Zne(s) + 3Rf(s) + Z0e(s)]

其中:

  • 等效负序阻抗: Zne(s) = [Zwn(s)(Zg1(s) + Zg2(s))] / [Zwn(s) + Zg1(s) + Zg2(s)]
  • 等效零序阻抗: Z0e(s) = [Z01(s)Z02(s)] / [Z01(s) + Z02(s)]

技术创新点

  1. 宽频特性: 与传统序网络不同,WCSIM在宽频范围内有效,但仅适用于特定工作点的小信号分析
  2. 序分量耦合: 首次建立了故障条件下序分量间的小信号互连模型
  3. 通用性: 不仅适用于故障系统,也适用于具有不平衡负载的系统
  4. 直观性: 通过等效阻抗直接评估系统稳定性

实验设置

测试系统参数

输电线路参数 (基准容量300MVA)

符号数值 p.u符号数值 p.u
RL1, XL10.0058+j0.058XT20.03
RL2, XL20.041+j0.41Rf0.02

PMSG参数 (基准容量2MVA)

  • 电流控制器: kpc=0.015, kic=3
  • 锁相环: kpp=0.48, kip=43
  • 陷波滤波器: ωN=200π, ζN=1
  • 滤波器: Lf=3mH, Cf=50μF, Rcf=1.5Ω

验证方法

  1. 频率扫描: 验证理论推导的WCSIM正确性
  2. 控制器硬件在环测试: 验证分析方法的有效性
  3. 对比实验: 比较有无小信号序互连(SSSI)的系统响应

实验场景

  • 故障位置: 220kV线路距风电场侧10%处发生单相接地故障
  • 对比案例:
    • 仅单相电压跌落
    • 实际单相接地故障

实验结果

主要结果

1. 频率扫描验证

  • 阻抗匹配: 测量的电网阻抗Z'gpe(s)与理论结果在幅值和相位上完全匹配
  • SSSI影响: 小信号序互连使电网阻抗幅值在整个频率范围内降低,相位保持不变
  • 稳定性改善: 原本相交的PMSG和电网阻抗曲线在考虑SSSI后不再相交,增加了超同步相互作用模式的阻尼

2. Nyquist分析

  • 不考虑SSSI: Nyquist曲线包围(-1, j0)点,系统不稳定
  • 考虑SSSI: 曲线不包围(-1, j0)点,系统变为稳定

3. 硬件在环测试结果

  • 单相电压跌落: PCC电压出现振荡但保持稳定
  • 单相接地故障: PCC电压振荡但系统稳定
  • 正序电压: 两种情况下正序PCC电压Vp均保持290V不变

关键发现

  1. SSSI稳定化作用: 序分量间的小信号互连具有稳定化作用,降低了系统阻抗
  2. 理论与实验一致: 理论分析与实验结果高度一致,验证了WCSIM的准确性
  3. 故障类型影响: 实际故障比单纯电压跌落具有更好的稳定性表现

相关工作

主要研究方向

  1. 平衡系统分析: 现有宽频振荡分析方法主要针对平衡系统
  2. 风电系统研究: 关注PLL、有功无功电流分配、正负序耦合对稳定性的影响
  3. 传统序网络: 用于传统电力系统不平衡故障的稳态分析

本文优势

  1. 扩展到宽频: 将序网络概念扩展到宽频分析
  2. 电力电子系统: 专门针对电力电子化系统
  3. 小信号框架: 建立了完整的小信号分析框架

结论与讨论

主要结论

  1. WCSIM有效性: 提出的宽频复合序阻抗模型能够准确评估不平衡条件下的系统相互作用
  2. 稳定化机制: 序分量间的小信号互连具有稳定化作用
  3. 广泛适用性: 方法不仅适用于故障系统,也适用于不平衡负载系统

局限性

  1. 特定工作点: WCSIM依赖于特定的平衡工作点,仅适用于小信号分析
  2. 单相故障: 当前主要针对单相接地故障进行验证
  3. 理论框架: 需要进一步扩展到其他类型的不平衡条件

未来方向

  1. 多种故障类型: 扩展到相间短路等其他故障类型
  2. 不平衡负载: 深入研究不平衡负载系统的应用
  3. 控制策略优化: 基于WCSIM开发改进的控制策略

深度评价

优点

  1. 理论创新: 首次将序网络理论扩展到电力电子系统宽频分析,具有重要理论价值
  2. 方法实用: 提供了直观的稳定性评估方法,工程实用性强
  3. 验证充分: 通过理论推导、频率扫描和硬件在环测试多重验证
  4. 数学严谨: 数学推导严密,物理意义清晰

不足

  1. 验证范围: 仅在PMSG系统上验证,需要在更多类型的电力电子设备上测试
  2. 故障类型单一: 主要针对单相接地故障,其他不平衡条件验证不足
  3. 参数敏感性: 未充分讨论系统参数变化对WCSIM准确性的影响

影响力

  1. 学术贡献: 为不平衡电力电子系统分析提供了新的理论工具
  2. 工程价值: 可指导实际电力系统的稳定性分析和控制设计
  3. 可复现性: 提供了详细的参数和实验设置,便于复现

适用场景

  1. 风电场接入: 适用于大规模风电场在不平衡条件下的稳定性分析
  2. 弱电网系统: 特别适用于电力电子设备接入弱电网的场景
  3. 故障分析: 可用于电网故障期间的系统行为预测和分析

参考文献

论文引用了30篇相关文献,主要涵盖:

  • 电力电子系统相互作用分析方法
  • 风电系统不平衡运行控制
  • 传统电力系统序网络理论
  • 小信号稳定性分析技术

总体评价: 这是一篇高质量的学术论文,在理论创新和实用性方面都有重要贡献。WCSIM方法填补了电力电子系统不平衡条件分析的理论空白,为相关领域研究提供了重要工具。论文结构清晰,验证充分,具有较高的学术价值和工程应用前景。