2025-11-14T08:25:14.041422

Overcoming light scattering with high optical nonlinearity

Szczypkowski, Makowski, Zwoliński et al.
While scattered light conveys most of the information we perceive, scattering may also distort that information before it reaches our detectors. The problem is acute in many applications, such as in high-resolution microscopy of biological tissue, where scattering degrades both resolution and signal-to-noise ratio. Here, for the first time, we demonstrate that uniting two intrinsic properties of scattered light: speckle statistics and the angular memory effect, with highly non-linear optical response yields, rather surprisingly, super-resolution, low-background, non-invasive imaging of objects completely hidden behind a strongly scattering, opaque layer. Crucially, our technique of non-invasive imaging through scatterers does not resort to wavefront shaping, adaptive optics, complicated optical setups, or iterative image reconstruction algorithms. Because the strategy relies solely on the properties of scattered light and high-order nonlinear response of the fluorophores, it can be applied to any speckle-forming propagation, from biological tissue to multicore fibres, combined with any type of phenomenon that exhibits a sufficiently high order nonlinearity.
academic

Overcoming light scattering with high optical nonlinearity

Basic Information

  • Paper ID: 2504.10423
  • Title: Overcoming light scattering with high optical nonlinearity
  • Authors: P. Szczypkowski, A. Makowski, W. Zwoliński, K. Prorok, P. Wasylczyk, A. Bednarkiewicz, R. Lapkiewicz
  • Author Affiliations: Faculty of Physics, University of Warsaw; École Normale Supérieure, Paris; Institute of Low Temperature and Structure Research, Polish Academy of Sciences
  • Classification: physics.optics, cond-mat.mtrl-sci, physics.bio-ph, physics.med-ph
  • Paper Link: https://arxiv.org/abs/2504.10423

Abstract

This study demonstrates for the first time that combining two intrinsic properties of scattered light—speckle statistics and angular memory effect—with highly nonlinear optical response enables super-resolution, low-background, non-invasive imaging capable of observing hidden objects through completely opaque, strongly scattering layers. This technique requires neither wavefront shaping, adaptive optics, complex optical apparatus, nor iterative image reconstruction algorithms. Instead, it relies solely on scattered light characteristics and the high-order nonlinear response of fluorophores, making it applicable to any speckle-forming propagation scenario, from biological tissue to multicore optical fibers.

Research Background and Motivation

Core Problem

Light scattering represents a fundamental challenge in modern optics, severely limiting application performance across multiple domains:

  1. Medical Diagnostics: Scattering compromises the accuracy of early-stage specific medical diagnosis
  2. Photodynamic Therapy: Affects the precision of targeted photodynamic therapeutic interventions
  3. Biological System Research: Impedes deep investigation of complex biological systems, such as live neuronal activity in brain tissue
  4. Fluorescence Microscopy: In fluorescence microscopy of neuronal activity, scattering severely degrades resolution and signal-to-noise ratio

Limitations of Existing Methods

Traditional deep-tissue imaging techniques—multiphoton microscopy—suffer from critical drawbacks:

  • Exponential Attenuation: Ballistic photon intensity exhibits unfavorable exponential decay with depth
  • Resolution Degradation: Scattering reduces resolution and ultimately limits achievable imaging depth
  • Complexity: Existing wavefront shaping and computational methods require complex hardware and demanding reconstruction algorithms
  • Diffraction Limitation: These methods remain fundamentally limited by diffraction

Research Motivation

The authors propose a fundamentally novel approach: leveraging the intrinsic properties of scattered light itself rather than attempting to compensate for or circumvent scattering, combined with high-nonlinearity response materials to achieve breakthrough imaging capabilities.

Core Contributions

  1. First Proposal of NISE Technology: Innovatively combines speckle statistics, angular memory effect, and high-order nonlinear optical response
  2. Achieves Super-Resolution Imaging: Implements sub-diffraction-limit imaging behind completely opaque scattering layers, with resolution λ/(2NA√m)
  3. Simplified Hardware Requirements: Eliminates the need for complex wavefront shaping, adaptive optics, or computational reconstruction algorithms
  4. Favorable Power Scaling: Demonstrates superior depth power scaling characteristics compared to ballistic-light-based methods
  5. Broad Applicability: Applicable to any speckle-forming propagation scenario and high-order nonlinear phenomena

Methodology Details

Task Definition

Input: Laser beam propagating through strongly scattering medium to illuminate marked samples hidden behind opaque scattering layers Output: High-resolution, low-background sample image Constraints: No ballistic photon transmission; relies solely on scattered light and nonlinear response

NISE Technology Principles

1. Speckle Excitation Mechanism

When a laser beam propagates through a scattering medium, it forms a speckle intensity pattern:

I_exc(x,y) = speckle intensity distribution

Speckles are formed by interference contributions from numerous small features, possessing diffraction-limited grain size: λ/(2NA)

2. Nonlinear Response Modeling

The luminescence intensity distribution of marked samples is described as:

I_lum(x,y) = R{I_exc(x,y)} · O(x,y)

where:

  • O(x,y): spatial distribution of luminescent markers (unknown)
  • R{·}: optical response function of the marker

For nonlinear response: R{I_exc} ∝ (I_exc)^m

3. Sparsification of Effective Excitation

As nonlinearity order m increases:

  • Linear Response (m=1): Effective excitation exhibits dense granular patterns
  • High Nonlinearity (m≫1): Effective excitation localizes to individual sub-diffraction spots

Key mathematical relationships:

  • Expected value of brightest speckle intensity: EI₁ = ⟨I⟩H_M ∼ ⟨I⟩(ln M + γ)
  • Sub-diffraction resolution: λ/(2NA√m)

4. Scanning Imaging

Through the angular memory effect, when the laser beam is tilted during scanning:

I_m(φ_x, φ_y) = ∬ R{I_exc(x-φ_x·d, y-φ_y·d)} · O(x,y) dxdy

Technical Innovations

  1. Integration of Statistical Optics and Nonlinearity: First systematic exploitation of speckle statistical properties for imaging
  2. Natural Super-Resolution: Achieves resolution enhancement through nonlinear response without requiring specialized optical design
  3. Depth Invariance: Speckle grain size maintains diffraction-limited characteristics during propagation
  4. Favorable Power Scaling: Brightest speckle intensity decays as ~(ln z)/z rather than exponentially

Experimental Setup

Experimental Apparatus

  • Excitation Source: 1064 nm continuous-wave laser
  • Microscopy System: Custom laser-scanning microscope
  • Objective Lens: Nikon CFI S Plan Fluor ELWD 20XC (NA=0.45)
  • Detector: Silicon photomultiplier tube as bucket detector
  • Scanning System: Scanning module based on two optically conjugate galvanometric mirrors

Scattering Media

  1. Optical Diffuser: Completely opaque diffuser blocking ballistic photon transmission
  2. Brain Tissue Sections: Fresh calf brain tissue sections, 480 μm thick

Nonlinear Marker Materials

Avalanche Microcrystals (NaLuF₄:8%Tm³⁺)

  • Nonlinearity Order: m ≃ 10
  • Avalanche Threshold: Tens of kW·cm⁻²
  • Emission Wavelength: 800 nm
  • Characteristics: Excellent photostability

Avalanche Nanoparticles (β-NaYF₄:8%Tm³⁺)

  • Size: 20 nm diameter
  • Nonlinearity Order: m ≃ 6
  • Avalanche Threshold: Lower than microcrystals
  • Application: Quasicrystalline domain structures with lowest avalanche threshold at edges

Evaluation Metrics

  • Resolution: Measured via point spread function (PSF)
  • Contrast: Signal-to-background ratio
  • Imaging Fidelity: Comparison with reference images under non-scattering conditions

Experimental Results

Main Results

1. Super-Resolution Imaging Verification

Using NA=0.45 objective lens and 1064 nm excitation wavelength:

  • Theoretical Diffraction Limit: 1.2 μm
  • NISE-Achieved Resolution: 540 nm FWHM
  • Resolution Enhancement: Significant breakthrough beyond diffraction limit

2. Imaging Through Optical Diffuser

  • Scattering Condition: Completely opaque scattering layer with no ballistic photon transmission
  • Bright-Field Imaging: Microcrystals completely invisible
  • NISE Imaging: Clear visualization of microcrystal structures, highly consistent with results under non-scattering conditions

3. Imaging Through Biological Tissue

  • Tissue Thickness: 480 μm brain tissue section
  • Distance: Scattering layer approximately 3 mm from sample
  • Results: Successful imaging of nanoparticle quasicrystalline domain edges; image quality matches control group

Key Experimental Findings

  1. Spatial Dependence: Avalanche threshold is lowest at structural discontinuities (edges, vertices) and higher in planar regions
  2. Power Requirements: Optical diffuser requires approximately 1 W power; brain tissue requires 500 mW
  3. Signal-to-Noise Ratio: Under m=15 nonlinearity and 200 speckle grains, signal-to-background ratio exceeds 10

Statistical Analysis

Based on exponential distribution of speckle intensity, the cumulative distribution of intensity ratio R = I₂/I₁ is derived as:

P_R(r) = Γ(1/r + 1)Γ(M + 1) / Γ(M + 1/r)

Under 200 speckle grains: P(R < 0.85) = 0.43

Traditional Scattering Compensation Methods

  1. Wavefront Shaping: Pioneering work by Vellekoop and Mosk, compensating scattering through wavefront optimization
  2. Computational Methods: Utilizing linear operator properties of scattering for computational reconstruction
  3. Memory Effect: Exploiting angular memory effect for hidden sample imaging

Multiphoton Microscopy

  • Two-Photon/Three-Photon Microscopy: Relies on ballistic photons for localized fluorescence emission
  • Limitations: Beyond several transport mean free paths depth, ballistic photon intensity becomes too low

Innovation of This Work

NISE represents a third strategy, standing alongside wavefront shaping and computational methods, opening a new frontier in scattering medium imaging.

Conclusions and Discussion

Main Conclusions

  1. Technical Breakthrough: NISE achieves the first sub-diffraction imaging through completely opaque media
  2. Mechanism Innovation: Exploits synergistic effects of speckle statistics and high-order nonlinear response
  3. Practical Advantages: Simple hardware, no complex algorithms required, insensitive to optical aberrations

Limitations

  1. Power Requirements: Requires high excitation power (10-100 kW·cm⁻²), potentially unsuitable for live biological imaging
  2. Material Constraints: Depends on specific avalanche particles; biological labeling protocols remain under development
  3. Speckle Number: Image quality degrades when multiple speckles have comparable brightness

Future Directions

  1. Threshold Reduction: Develop materials with lower avalanche thresholds to reduce excitation intensity
  2. Hybrid Methods: Combine wavefront shaping and computational reconstruction to enhance performance
  3. Extended Applications:
    • Fiber bundle endoscope implementation
    • Multifunctional probes (pH, FRET, temperature sensing)
    • Materials processing, laser surgery, photodynamic therapy, optogenetics

In-Depth Evaluation

Strengths

  1. Conceptual Innovation: First systematic exploitation of advantageous properties of scattered light rather than avoiding scattering
  2. Theoretical Rigor: Provides comprehensive statistical optics theoretical framework and mathematical derivations
  3. Sufficient Experimental Validation: Encompasses verification across different scattering media and marker materials
  4. Practical Value: Simple hardware, easy to implement and promote

Technical Highlights

  1. Depth Scaling Advantage: Superior deep-tissue penetration capability compared to exponentially decaying ballistic photon methods
  2. Aberration Insensitivity: Due to illumination randomization, insensitive to optical aberrations in excitation system
  3. Resolution-Depth Decoupling: Super-resolution capability remains independent of depth variation

Potential Impact

  1. Academic Impact: Likely to catalyze new research directions in scattered light imaging
  2. Application Prospects: Broad application potential in biomedical imaging, materials science, and related fields
  3. Technology Promotion: Provides novel approaches for other applications requiring imaging through scattering media

Applicable Scenarios

  1. Biomedical: Deep tissue imaging, neuroscience research
  2. Materials Science: Porous materials, composite material internal structure investigation
  3. Industrial Applications: Quality control, non-destructive testing
  4. Communications: Multicore fibers, fiber bundle imaging

References

The paper cites 36 important references spanning key domains including scattered light optics, multiphoton microscopy, wavefront shaping, and avalanche luminescence, providing solid theoretical foundation and technical background for this research.


Overall Assessment: This is a groundbreaking work of significant importance in the field of optical imaging. Beyond achieving major technical innovation, it conceptually opens new research directions in scattered light optics. While power requirements and material limitations require further improvement, the demonstrated principles and potential offer entirely new possibilities for future deep-tissue biological imaging and related applications.