Hänsch-Couillaud locking of a large Sagnac interferometer: advancing below the flicker floor
Zenner, Schreiber, Stellmer
Large Sagnac interferometers in the form of active ring lasers have emerged as unique rotation sensors in the geosciences, where their sensitivity allows to detect geodetic and seismological signals. The passive laser gyroscope variant, however, is still at a stage of development, and adequate laser frequency stabilization techniques are explored to reach the desired levels of sensitivity and stability. Here, we present the first Hänsch-Couillaud locked passive laser gyroscope. We employ a lock-in scheme to overcome the flicker floor to achieve a sensitivity of 3.1 nrad/s, corresponding to a fraction of $7.7 \cdot 10^{5}$ in the Earth's rotation rate.
academic
Hänsch-Couillaud locking of a large Sagnac interferometer: advancing below the flicker floor
Large Sagnac interferometers appear in Earth sciences as unique rotation sensors in the form of active ring lasers, with sensitivity allowing detection of geodetic and seismic signals. However, passive laser gyroscope variants remain under development, exploring appropriate laser frequency stabilization techniques to achieve required sensitivity and stability levels. This paper presents for the first time a passive laser gyroscope with Hänsch-Couillaud locking, employing a phase-locking scheme to overcome the flicker noise floor, achieving a sensitivity of 3.1 nrad/s, corresponding to 7.7×10⁻⁵ times Earth's rotation rate.
The core problem addressed by this research concerns the improvement of laser frequency stabilization techniques in passive laser gyroscopes. Specifically:
Technical Challenges: Passive laser gyroscopes require external lasers simultaneously stabilized to both clockwise and counterclockwise cavity resonance modes, imposing extremely high demands on laser frequency stability
Limitations of Existing Methods: All current passive laser gyroscopes employ Pound-Drever-Hall (PDH) locking schemes, which suffer from residual amplitude modulation (RAM) problems
RAM Problem: Asymmetry in the phase of frequency modulation sidebands caused by optical elements leads to non-zero error signal baseline and fluctuations
Earth Science Applications: High-precision rotation measurement is crucial in geodesy, seismology, and fundamental physics research
Technical Advantages: Passive laser gyroscopes avoid gain media and laser plasma in active ring lasers, eliminating lock-in effects, backscattering, and plasma dynamics issues
Precision Requirements: Measurement precision at the 10⁻⁴-10⁻⁵ level of Earth's rotation rate is needed
To find alternative approaches to PDH locking schemes that fundamentally avoid the root causes of RAM problems, improving measurement precision and long-term stability of passive laser gyroscopes.
Input: External laser frequency signal
Output: Laser beams stably locked to both clockwise and counterclockwise modes of the ring cavity
Objective: Minimize noise in Sagnac frequency measurement, achieving high-precision rotation rate detection
This paper cites 31 important references covering fundamental theory of the Sagnac effect, ring laser technology, frequency stabilization methods, and related experimental techniques, providing solid theoretical and technical foundation for the research.
Overall Assessment: This is a technically innovative and rigorously designed optical precision measurement paper that successfully demonstrates the application potential of HC locking in passive laser gyroscopes, providing valuable new insights for technological development in this field.