Characterization of noise of a quantum harmonic oscillator is important for many experimental platforms. We experimentally demonstrate motional spin-locking spectroscopy, a method that allows us to directly measure the motional noise spectrum of a quantum harmonic oscillator. We measure motional noise of a single trapped ion in a frequency range from 200 Hz to 5 kHz with a power spectral density that resolves noise over two orders of magnitude. Coherent modulations in the oscillation frequency of the oscillator can be probed with a relative frequency sensitivity at the $10^{-6}$ level.
Noise characterization of quantum harmonic oscillators is crucial for many experimental platforms. This paper experimentally demonstrates the motion spin-locking spectroscopy method, which allows direct measurement of the motion noise spectrum of quantum harmonic oscillators. The researchers measured the motion noise of a single trapped ion in the frequency range of 200 Hz to 5 kHz, with power spectral density resolution spanning two orders of magnitude in noise. Coherent modulation in the oscillator frequency can be detected at the 10−6 level.
Core Problem: In quantum computing and quantum simulation platforms, control of the motion state of trapped particles is critical. Whether charged ions in radiofrequency traps or neutral atoms in optical tweezer arrays, particles must be cooled near the motion ground state and maintain stable motion to achieve high-fidelity quantum operations.
Problem Significance:
Two-qubit entangling operations (such as Mølmer-Sørensen gates) use common motion modes to mediate entanglement between qubits
Fluctuations in the trapping potential perturb the motion state, leading to quantum gate operation errors
Therefore, characterization of noise acting on trapped particles is necessary
Limitations of Existing Methods:
Ramsey experiments with Fock state superpositions
Motion spin-echo experiments with displaced coherent states
CPMG-type experiments with displaced cat states
Response measurements with modulated periodic driving
These methods either only indirectly obtain the noise spectrum or require experimental determination of response functions to reconstruct the spectrum
Research Motivation: Develop a method capable of directly measuring the noise spectrum of quantum harmonic oscillators, particularly for (harmonic) trapped ion systems.
Experimentally demonstrated the motion spin-locking spectroscopy method, capable of directly measuring the noise spectrum of quantum harmonic oscillators
Measured motion noise of a single trapped ion in the frequency range of 200 Hz to 5 kHz, with power spectral density resolution spanning two orders of magnitude
Achieved relative frequency sensitivity at the 10−6 level, capable of detecting coherent modulation in the oscillator frequency
Provided a tool for improving charged particle trap stability, applicable to other systems with external degrees of freedom
The task studied in this paper is to develop and validate a method for directly measuring the motion noise spectrum of quantum harmonic oscillators. The input is the motion state of a trapped ion system, and the output is the noise power spectral density in a specific frequency range.
Coherent Motion State Preparation: Using electric fields resonant with the ion oscillation frequency to prepare coherent motion states, rather than attempting to prepare high Fock states
Optimal Displacement Selection: Selecting average phonon number nˉ=610 to maximize sideband coupling strength
Dual Transition Contrast: Simultaneously measuring carrier and motion sideband transitions to distinguish different noise sources
Contrast the noise spectrum of motion sideband transitions with that of carrier transitions to distinguish motion noise from laser/magnetic field noise.
Figure 3(b) shows the time evolution of several noise peaks, where magnetization exhibits damped oscillations rather than simple exponential decay, indicating these peaks have considerable coherence. By fitting the damped oscillation form of equation (5), both the modulation index and noise spectral density can be extracted simultaneously.
Noise Source Identification: Motion noise peaks appear only in sideband transitions, confirming their origin from confinement frequency fluctuations
Coherent Characteristics: Some noise peaks display coherent modulation characteristics, possibly originating from electronic stabilization circuits of the trap driving signal
Frequency Limitations:
Low frequency end: Strong noise exceeds weak noise approximation range
Successfully demonstrated the motion spin-locking spectroscopy method, capable of directly measuring the motion noise spectrum of quantum harmonic oscillators
Achieved high-precision noise measurement in the 200 Hz-5 kHz range, with power spectral density resolution spanning two orders of magnitude
Achieved relative frequency sensitivity at the 10−6 level, capable of detecting coherent frequency modulation
The paper cites 16 important references covering key areas including Mølmer-Sørensen gates, various noise measurement techniques, spin-locking spectroscopy theory and applications, providing a solid theoretical foundation and experimental comparison for this research.
Overall Assessment: This is a high-quality experimental physics paper making important contributions to the field of quantum noise spectroscopy. The method is novel, the experimental design is ingenious, the results are reliable, and it has significant practical value for quantum information processing and precision measurement fields.