Solid-state nanopore and nanopipette sensors are powerful devices for the detection, quantification and structural analysis of biopolymers such as DNA and proteins, especially in carrier-enhanced resistive-pulse sensing. However, hundreds of different molecules typically need to be sampled from solution and analysed to obtain statistically robust information. This limits the applicability of such sensors and complicates associated workflows. Here, we present a new strategy to trap DNA structures in the sensing region of a nanopipette through end functionalisation and nanoparticle capping. We develop a robust set of descriptors to characterise the insertion and presence of nanoparticle-DNA constructs in the nanopipette tip and, furthermore, show that they remain mobile and responsive to external electric fields over extended periods of time. This allows for repeated readout of the same DNA structure and could enable new applications for such sensors, for example in flow and in confined environments.
academic

Constructing a Nanopipette-based DNA Electro-Mechanical Device

Basic Information

  • Paper ID: 2510.10515
  • Title: Constructing a Nanopipette-based DNA Electro-Mechanical Device
  • Authors: Cengiz J. Khan, Oliver J. Irving, Rand A. Al-Waqfi, Giorgio Ferrari, Tim Albrecht
  • Classification: cond-mat.mes-hall physics.app-ph
  • Publication Date/Conference: 2025 (Preprint)
  • Paper Link: https://arxiv.org/abs/2510.10515
  • Institution: University of Birmingham, School of Chemistry

Abstract

Solid-state nanopores and nanopipette sensors are powerful devices for detecting, quantifying, and structurally analyzing biopolymers such as DNA and proteins, particularly in resistive pulse sensing with carrier enhancement. However, sampling and analyzing hundreds of different molecules from solution is typically required to obtain statistically robust information. This limitation restricts the applicability of such sensors and complicates associated workflows. This paper proposes a novel strategy for capturing DNA structures in the sensing region of a nanopipette through terminal functionalization and nanoparticle capping. The study develops a robust set of descriptors to characterize the insertion and presence of nanoparticle-DNA constructs at the nanopipette tip, and further demonstrates that they maintain mobility over extended periods and respond to external electric fields. This enables repeated readout of identical DNA structures and potentially opens new applications for such sensors, including those in flow and confined environments.

Research Background and Motivation

Problem Definition

The core challenges faced by nanopore sensors in biomolecular detection are:

  1. High Statistical Requirements: Detection of hundreds of different molecules is necessary to obtain statistically reliable information
  2. Molecular Loss: Molecules are lost after transiting the nanopore and cannot be repeatedly detected
  3. Complex Workflows: Traditional methods limit sensor applications in complex environments

Research Significance

This research is important for advancing nanopore sensing technology:

  • Enables repeated readout of individual DNA structures
  • Simplifies bioanalytical workflows
  • Extends sensor applicability in flow and confined environments
  • Provides a new platform for carrier-enhanced sensing technology

Limitations of Existing Methods

Traditional nanopore sensing methods have the following constraints:

  • Molecules cannot be recovered after transit, requiring large sample volumes
  • Multiple measurements on the same molecule are not feasible
  • Applications in complex environments (e.g., intracellular, flow conditions) are limited
  • Sample processing and sensing procedures cannot be effectively integrated

Core Contributions

  1. Development of a Nanopipette-based DNA Electro-Mechanical Device (NEMD): Combining DNA engineering, nanoparticle chemistry, and electrophoretically-driven assembly
  2. Establishment of a preparation and characterization system for DNA-nanoparticle dumbbell structures: Using orthogonal functionalization strategies for controlled assembly
  3. Proposal of novel electrical descriptors: Development of parameters such as ΔIDC and ΔσAC to distinguish insertion events from conventional translocation events
  4. Achievement of repeatable single-molecule detection: Demonstration that captured DNA structures can undergo bidirectional motion and repeated readout under electric field
  5. Verification of long-term structural stability: Maintenance of structural integrity and responsiveness over periods exceeding 3000 seconds

Detailed Methodology

Task Definition

Construction of a nano-electromechanical device capable of permanently trapping DNA carrier molecules in the sensing region of a nanopipette, achieving:

  • Input: Terminal-functionalized 5 kbp DNA and two differently modified gold nanoparticles
  • Output: Stably trapped NP/DNA/NP dumbbell structure in the nanopipette
  • Constraints: Nanoparticle diameter must exceed the nanopipette inner diameter to prevent complete transit

Device Architecture

1. DNA Preparation

  • PCR amplification to prepare 5 kbp DNA fragments
  • Terminal modification with azide and biotin groups at the 5' ends
  • Orthogonal functionalization at both ends for specific nanoparticle binding

2. Nanoparticle Modification

  • DBCO-modified gold nanoparticles: Coupling with azide groups via copper-free click chemistry
  • Streptavidin-modified gold nanoparticles: Coupling via biotin-streptavidin interaction
  • Particle diameter: 40±2 nm, exceeding nanopipette inner diameter (~20 nm)

3. Assembly Strategy

Step 1: DBCO-NP + azide-DNA → DBCO-NP/DNA complex
Step 2: Electrophoretic driving of complex into nanopipette
Step 3: Internal streptavidin-NP binding to biotin terminus
Step 4: Formation of complete NP/DNA/NP dumbbell structure

Technical Innovations

1. Orthogonal Functionalization Strategy

  • Utilization of DBCO-azide click chemistry and biotin-streptavidin systems
  • Ensures specific binding and prevents non-specific aggregation
  • Enables precise control of stepwise assembly

2. Electrical Detection Method

Introduction of novel analytical parameters:

  • ΔIDC: Direct current change, reflecting sustained conductance change after structure insertion
  • ΔσAC: Alternating current channel noise change, indicating dynamic processes and charge redistribution

3. Dual-Channel Signal Processing

  • DC Channel: Detection of slow modulation (fDC ≈ 7 Hz and below)
  • AC Channel: Detection of rapid modulation (up to 2 MHz)
  • Frequency-domain separation enables distinction between insertion and conventional translocation events

Experimental Setup

Material Preparation

  • DNA: 5 kbp fragments from PCR amplification of λ-DNA template
  • Nanoparticles: 40 nm gold nanoparticles, separately modified with DBCO and streptavidin
  • Nanopipette: Quartz capillary pulled to ~20 nm inner diameter
  • Electrolyte: 4 M LiCl solution

Characterization Methods

  1. Gel Electrophoresis: 1% agarose gel to verify DNA-nanoparticle binding
  2. Transmission Electron Microscopy (TEM): Direct observation of dumbbell structure formation
  3. Electrical Measurements: I-V characteristic curves and real-time current recording
  4. Optical Tracking: Magnetic microsphere tracking to verify capture and motion

Detection Parameters

  • Event Detection Threshold: 5σAC
  • Sampling Frequency: 1 MHz
  • Recording Duration: 1000 seconds per condition
  • Voltage Range: ±0.2 V to ±0.8 V

Experimental Results

Main Results

1. Successful Assembly Verification

  • Gel Electrophoresis: Significantly reduced migration rate after DNA-NP binding
  • TEM Imaging: Direct observation of dumbbell-shaped structures
  • Conductance Measurement: Decrease from 47.2 nS to 46.5 nS, indicating structure insertion

2. Insertion Event Characteristics

Compared to conventional DNA translocation, insertion events exhibit:

  • Duration: τ > 100 ms (two orders of magnitude longer than conventional translocation)
  • Current Amplitude: 150-500 pA
  • ΔIDC: Average -1% (sustained conductance reduction)
  • ΔσAC: Average +20% (noise increase)

3. Long-Term Stability

  • Maintained stability over 3000 seconds within ±0.6 V to ±0.8 V voltage range
  • Structure not expelled after voltage reversal, confirming successful capture
  • Translocation frequency reduced by approximately 4-fold, indicating reduced effective area

4. Mobility Verification

Optical tracking experiments using 1 μm magnetic microspheres:

  • At +1 V, microsphere distance from nanopipette tip: 1.2±0.25 μm
  • At -1 V, microsphere pulled back near the tip
  • Verified bidirectional motion capability of DNA molecular chains

Statistical Analysis

  • Number of Insertion Events: N ≈ 26 long-duration events
  • Conductance Change Consistency: All insertion events showed negative ΔIDC
  • Noise Change Consistency: All insertion events showed positive ΔσAC

Nanopore Sensing Technology

This research builds upon existing nanopore sensing technology:

  • Resistive pulse sensing principles
  • Carrier-enhanced detection methods
  • DNA origami nanopore technology

DNA Nanotechnology

Incorporates established methods from DNA nanotechnology:

  • DNA functionalization and modification techniques
  • Nanoparticle-DNA coupling methods
  • Bioorthogonal chemical reactions

Single-Molecule Detection

Compared to traditional single-molecule detection methods:

  • Overcomes the limitation of "one-time" detection
  • Enables repeated measurements on identical molecules
  • Provides a new platform for dynamic sensing

Conclusions and Discussion

Main Conclusions

  1. Successfully developed a nanopipette-based DNA electro-mechanical device
  2. Achieved controlled assembly and permanent capture of DNA-nanoparticle dumbbell structures
  3. Established an electrical descriptor system to distinguish insertion from translocation events
  4. Verified long-term stability and electric field responsiveness of captured structures

Limitations

  1. Assembly Efficiency: Relatively few insertion events; optimization of assembly conditions needed
  2. Structural Diversity: Currently verified only for single DNA length and nanoparticle size combinations
  3. Quantitative Analysis: Lack of quantitative assessment of capture efficiency and structural integrity
  4. Application Verification: Performance not yet validated in practical bioanalytical applications

Future Directions

  1. Functionalization Extension: Introduction of specific capture probes on DNA
  2. Multiplex Detection: Development of simultaneous detection capability for multiple targets
  3. Microfluidic Integration: Integration with microfluidic systems for automation
  4. Single-Cell Applications: Exploration of applications in confined intracellular environments

In-Depth Evaluation

Strengths

  1. Conceptual Innovation: First demonstration of permanent capture and repeated readout of DNA carriers
  2. Technical Rigor: Multiple characterization methods verify structure formation and function
  3. Comprehensive Methodology: Complete system for preparation, characterization, and detection
  4. Application Prospects: Opens new application directions for nanopore sensing technology

Weaknesses

  1. Limited Efficiency: Lower insertion success rate requires further optimization
  2. Mechanism Understanding: Physical principles underlying noise increase insufficiently explained
  3. Lack of Standardization: Absence of standardized performance evaluation metrics
  4. Cost Considerations: Use of gold nanoparticles increases costs

Impact

  1. Academic Value: Provides new research direction for nanopore sensing field
  2. Technical Breakthrough: Addresses important limitations of traditional methods
  3. Application Potential: Broad prospects in biomedical detection and single-cell analysis
  4. Reproducibility: Provides detailed experimental protocols and parameters

Applicable Scenarios

  1. Carrier-Enhanced Sensing: Improves detection accuracy and reproducibility
  2. Flow Environment Detection: Suitable for continuous monitoring applications
  3. Confined Space Analysis: Applications in intracellular or microfluidic environments
  4. Dynamic Process Monitoring: Real-time tracking of molecular interactions

References

The paper cites 38 relevant references covering important works in nanopore sensing, DNA nanotechnology, single-molecule detection, and other related fields, providing a solid theoretical foundation for the research.


Overall Assessment: This is a paper of significant innovative importance in the field of nanopore sensing technology. Through clever design, it achieves permanent capture of DNA carriers, opening new directions for field development. While there is room for improvement in efficiency and mechanism understanding, the value of its conceptual innovation and technical breakthrough is undeniable.