We present a prism-coupled packaging strategy for whispering-gallery mode resonators (WGMRs). Utilizing an all-solid-state optical adhesive process with active temperature control and hermetic sealing, the package exhibits exceptional long-term stability and environmental robustness. A standalone WGMR module was characterized, demonstrating a temperature sensitivity below 10^-7 /°C and a low-frequency Z-axis acceleration sensitivity below 10^-10 /g. The module was applied as a stable optical frequency reference, achieving a short-term frequency stability of 2x10^-13 at 2 ms, and as a nonlinear photonic platform, generating Kerr soliton microcombs with a pump power of 100 mW. This compact, robust packaging solution enhances the applicability of WGMRs in real-world applications such as narrow-linewidth lasers and portable microcombs, facilitating the transition from laboratory research to practical deployment.
- Paper ID: 2510.10939
- Title: Packaging of Low-Environmental-Sensitivity WGM Resonators for Practical Applications
- Authors: Jiajun Wu, Xuanqi Wang, Chengyu Zhang, Chenghong Li, Shan Zhong, and Songbai Kang
- Classification: physics.optics
- Publication Date/Venue: Journal information not explicitly specified (manuscript stage)
- Paper Link: https://arxiv.org/abs/2510.10939
This paper proposes a packaging strategy for whispering gallery mode resonators (WGMRs) based on prism coupling. The approach employs an all-solid-state optical bonding process combined with active temperature control and hermetic sealing, demonstrating excellent long-term stability and environmental robustness. Independent WGMR modules exhibit temperature sensitivity below 10⁻⁷/℃ and low-frequency Z-axis acceleration sensitivity below 10⁻¹⁰/g. The module achieves short-term frequency stability of 2×10⁻¹³@2ms as a stable optical frequency reference and generates Kerr soliton microcombs with 100mW pump power as a nonlinear photonic platform. This compact and robust packaging solution significantly enhances the applicability of WGMRs in practical applications such as narrow-linewidth lasers and portable microcombs.
Whispering gallery mode resonators (WGMRs) are widely used in advanced laboratory applications including optical sensing, narrow-linewidth lasers, frequency combs, and nonlinear optics due to their compact size, high quality factor (Q), and small mode volume. However, WGMRs face the following critical challenges:
- Environmental Sensitivity: Surface contaminants (moisture, dust) severely degrade the Q factor; temperature fluctuations and vibrations cause resonant frequency drift
- Operational Complexity: Requires precision mechanical coupling devices, microscope alignment systems, and specialized operational expertise
- Practical Limitations: Current technology struggles to transition from laboratory environments to real-world applications
Current reported WGMR packaging primarily employs tapered fiber coupling, presenting the following issues:
- High sensitivity to vibration-induced coupling fluctuations
- The tapering process compromises the polarization-maintaining properties of optical fibers, reducing input light polarization purity
- Lack of selective single-mode coupling tuning capability
While prism coupling can address these issues, implementation challenges include: critical optical alignment to couple into the ultra-small mode area of the resonator, and ultra-low aging requirements for displacement between the prism, WGMR, and collimator during adhesive curing.
- Innovative Packaging Technology: First complete packaging solution for prism-coupled WGMRs using all-solid-state optical bonding process
- Excellent Environmental Stability: Achieves temperature sensitivity <10⁻⁷/℃ (one order of magnitude improvement over bare resonators) and acceleration sensitivity <10⁻¹⁰/g
- Long-term Stability Verification: No significant degradation of critical optical parameters over 6-month testing period
- Dual-function Application Demonstration: Successful verification as both optical frequency reference and nonlinear photonic platform
- Practical Implementation Breakthrough: Compact 73cm³ packaging achieving plug-and-play functionality
WGMR Fabrication:
- Material: Magnesium fluoride (MgF₂)
- Manufacturing process: Single-point diamond turning
- Geometric parameters: 6mm diameter, 0.5mm thickness
- Edge width: Approximately 25μm (suppresses higher-order mode excitation)
- Performance metrics: Q factor ~2×10⁹@1.5μm, fundamental mode volume ~40μm²
Core Components:
- Temperature Control System: Integrated thermoelectric cooler (TEC) and tungsten-copper heat sink
- Sealing Structure: Coupling prism, glass frame, and cover plate forming sealed cavity
- Optical System: Polarization-maintaining fiber collimator, polarizer (>20dB extinction ratio)
- Bonding System: Ultra-low thermal expansion UV adhesive
Packaging Process:
- Sequential UV curing followed by final high-temperature curing
- Ensures coupling stability and residual stress dissipation
- Integrated active temperature stabilization
- Prism Coupling Advantages:
- Preserves polarization characteristics
- Supports selective single-mode coupling
- Low vibration sensitivity
- All-Solid-State Bonding:
- Ultra-low thermal expansion coefficient
- Ensures long-term stability
- Minimizes residual stress
- Integrated Temperature Control:
- Active TEC control
- Significantly reduces temperature sensitivity
- Enhances long-term frequency stability
Q Factor Testing:
- Method: Ring-down technique
- Testing period: 6-month long-term monitoring
- Sample size: 4 packaged modules
Temperature Sensitivity Testing:
- Laser locking: Pound-Drever-Hall (PDH) technique
- Frequency monitoring: High-resolution wavelength meter (Bristol 621A)
- Reference source: Hydrogen maser reference optical frequency comb
Acceleration Sensitivity Testing:
- Vibration platform: 10-100Hz range, 10Hz increments
- Measurement axis: Z-axis (most sensitive direction)
- Locking bandwidth: Approximately 1kHz
- Synchronized measurement: Accelerometer data and laser phase noise
Optical Frequency Reference:
- Laser stabilization: Custom DFB laser PDH locking
- Performance evaluation: Phase noise and frequency stability measurements
Nonlinear Applications:
- Kerr soliton generation: 100mW input power
- Spectral analysis: Single-soliton state characterization
Coupling Efficiency and Stability:
- Coupling efficiency: >90% (approaching tapered fiber coupling performance)
- Insertion loss: Approximately 2dB
- Long-term stability: No significant degradation over 6 months
Optical Quality:
- Q factor: Maintained at 2×10⁹ level
- Free spectral range: Approximately 11.5GHz
- Mode characteristics: 6 modes per FSR (few-mode WGMR)
Temperature Characteristics:
- Bare MgF₂ WGMR: Approximately -500MHz/℃
- Packaged device (without temperature control): Approximately +50MHz/℃
- With active temperature control: <10⁻⁷/℃ (>10× improvement)
- Long-term stability: Frequency fluctuation ≤5MHz within 10⁴s
Acceleration Sensitivity:
- Z-axis sensitivity: <1.63×10⁻¹⁰/g (10-100Hz range)
- Peak sensitivity: 10⁻¹⁰/g@10Hz and 30Hz (mechanical resonances)
- Other frequencies: <10⁻¹¹/g
- Theoretical consistency: Agrees with literature predictions of 10⁻¹⁰/g
Optical Frequency Reference:
- Phase noise suppression: >25dB near 1kHz
- Frequency stability: 2×10⁻¹³@2ms
- Noise limit: Approaching thermal-refractive noise limit
Nonlinear Optics:
- Kerr soliton generation: Successfully achieved with 100mW pump power
- Single-soliton stable operation
- Good microcomb spectral characteristics
- Tapered Fiber Coupling: Mainstream approach but with polarization and stability issues
- Commercial Products: OEwaves Inc.'s prism-coupled modules, but technical details and performance data lack public documentation
- Theoretical prediction of acceleration sensitivity approximately 10⁻¹⁰/g
- Existing experimental data sparse; this work provides first systematic verification
- Quantitative analysis of temperature sensitivity improvement
- Technical Breakthrough: First complete packaging solution for prism-coupled WGMRs
- Superior Performance: Temperature sensitivity <10⁻⁷/℃, acceleration sensitivity <10⁻¹⁰/g
- Long-term Stability: 6-month testing verifies packaging reliability
- Application Verification: Successful demonstration of dual functionality as optical frequency reference and nonlinear photonic platform
- Temperature Gradient: Temperature gradient exists between sensor location and WGMR, affecting control precision
- Mechanical Resonances: Packaging mechanical resonances at 10Hz and 30Hz require design optimization
- Cost Considerations: While simplified compared to laboratory equipment, precision manufacturing costs still require evaluation
- Thermal Design Optimization: Reduce thermal gradients, further improve temperature stability
- Mechanical Design Improvement: Eliminate mechanical resonances, enhance vibration immunity
- Mass Production Development: Develop manufacturing processes suitable for industrialization
- Multi-wavelength Extension: Adapt to different wavelength application requirements
- Strong Innovation: First systematic solution to WGMR practical packaging challenges
- Comprehensive Experiments: Complete characterization of long-term stability, environmental sensitivity, and application performance
- Advanced Technology: Performance metrics meet or exceed theoretical expectations
- High Practical Value: Directly promotes WGMR transition from laboratory to industrial applications
- Insufficient Theoretical Analysis: Lacks theoretical modeling and optimization analysis of packaging design
- Cost-Benefit Assessment Missing: No cost comparison with existing technologies provided
- Limited Application Scope: Primarily targets 1.5μm wavelength band; applicability to other bands requires verification
- Batch Consistency Unverified: Only 4 samples tested; large-scale production consistency requires verification
Academic Contributions:
- Fills gap in WGMR packaging technology
- Provides quantitative benchmarks for environmental sensitivity
- Establishes technical pathway for WGMR practical implementation
Industrial Value:
- Promotes precision optical device industrialization
- Supports portable optical frequency comb and narrow-linewidth laser development
- Provides stable platform for optical sensing and metrology applications
- Precision Metrology: Optical frequency standards, time-frequency transfer
- Laser Technology: Narrow-linewidth laser frequency stabilization reference
- Optical Communications: High-stability light sources and frequency combs
- Scientific Instruments: Portable optical frequency comb systems
- Industrial Inspection: High-precision optical sensing applications
The paper cites 15 relevant references covering:
- WGMR fundamental theory and applications 1-3
- Existing packaging technologies 6-8
- Environmental sensitivity theory and measurements 12-15
- Commercial products 11
Key references include Savchenkov et al.'s theoretical predictions on acceleration sensitivity and Zhang et al.'s experimental measurements, providing important theoretical foundation and comparison benchmarks for this work.