Basis for a hands free blood flow measurement with automated vessel focus
Fuchs, Sumrah, Schwerdt et al.
Cardiopulmonary resuscitation (CPR) is one of the essential tools to ensure oxygen supply during cardiac arrest. However, the precise effects of chest compression are not quantifiable to this day. This often results in a low quality of chest compressions even if performed by health-care professionals. One solution could be provided by quantification of blood flow via ultrasonic Doppler measurements, to guide first responders in their efforts. This paper presents an approach to address the issue of limited time, anatomical know how and limitations of system configuration during emergency scenarios. An approach for automated vessel identification with three different phases was developed, featuring a new sensor probe for ultrasonic measurements with non symmetrically angled piezo ceramics. The probe was used with prototype ultrasound hardware in a laboratory setup for Pulsed Wave Doppler (PW Doppler). In an initial measurement a qualitative flow was approximated to examine valuable measurement positions on a phantom. Afterwards an iterative mode was used for depth depending frequency measurements with score calculation of flow periodicity and signal power. The configuration with the best score was used for a prolonged monitoring mode. Flow values were compared to data of an industrial flow-sensor. Flow-sensor data showed an average coefficient of determination of 0.97 with an average root mean square error of 3.84 ml/s. With the proposed hardware and software solutions a basis for future developments was made, which could lead to a fully automated vessel identification during CPR. This device could provide first responders as well as clinical staff with vital information about CPR efficiency that has yet to be included into the therapy of people during cardiac arrest.
academic
Basis for a hands free blood flow measurement with automated vessel focus
Title: Basis for a hands free blood flow measurement with automated vessel focus
Authors: R. Fuchs, N. Sumrah, J. Schwerdt, M. Unger, G. Stachel, M. Schultz, K. Lenk, T. Neumuth
Classification: physics.med-ph eess.SP
Institutions: Innovation Center for Computer-Assisted Surgery, University of Leipzig; Department of Cardiology, University Hospital Leipzig; GAMPT Company; Merseburg University of Applied Sciences
Cardiopulmonary resuscitation (CPR) is a critical intervention to ensure oxygen supply during cardiac arrest. However, the precise efficacy of chest compressions cannot currently be quantified, resulting in poor CPR quality even when performed by medical professionals. Quantification of blood flow via ultrasound Doppler measurement can provide guidance to emergency responders. This paper proposes a method addressing time constraints, limited anatomical knowledge, and system configuration limitations in emergency situations. An automated vessel identification method comprising three distinct phases was developed, utilizing a novel sensor probe with asymmetric angle piezoelectric ceramics for ultrasound measurement. The probe and prototype ultrasound hardware were employed in a pulsed-wave (PW) Doppler laboratory setting. Initial measurements qualitatively assessed blood flow to identify effective measurement locations on phantoms, followed by iterative depth-correlated frequency measurements to calculate blood flow periodicity and signal power scores. Extended monitoring mode was performed using the optimal scoring configuration. Blood flow values were compared with industrial flow sensor data, demonstrating an average coefficient of determination of 0.97 and average root mean square error of 3.84 ml/s. The proposed hardware and software solution provides a foundation for future development that may enable fully automated vessel identification during CPR.
Inability to Quantify CPR Efficacy: The precise effect of chest compressions cannot currently be quantified in real-time, resulting in poor CPR quality
Absence of Cerebral Blood Flow Monitoring: Cerebral blood flow is a determinant of long-term survival, yet direct, non-invasive, and user-friendly measurement methods are lacking during resuscitation
Limitations of Existing Technology: While commercial ultrasound equipment can perform Doppler blood flow measurement, it lacks robust hands-free connection options during CPR and requires specialized knowledge
Input: Ultrasound signals from the carotid artery region
Output: Real-time blood flow velocity and volumetric flow rate
Constraints: Automated configuration must be completed within 5 seconds, applicable to emergency rescue scenarios
This paper cites 24 relevant references covering key research in CPR guidelines, blood flow monitoring technology, and ultrasound Doppler methods, providing solid theoretical foundation for the research.
Overall Assessment: This is a high-quality medical physics research paper proposing an innovative CPR blood flow monitoring solution. The technical methodology is novel, experimental verification is comprehensive, and it possesses significant clinical application value. Despite certain limitations, it opens new directions for field development and merits further clinical validation and commercialization exploration.