2025-11-17T13:25:12.597765

Compact Continuous Cold Atomic Beam from a Single Cell with 3D Cooling and Ultra-low Light Shift

Wang, Cai, Meng et al.
We report a compact single-cell source of a continuous cold-atom beam with three-dimensional (3D) cooling. By integrating an off-axis moving optical molasses (OM) with a two-dimensional magneto-optical trap (MOT), we achieve simultaneous 3D cooling within a 50 mm interaction region. The source delivers a continuous flux up to 4.9(5)x10^9 atoms/s, with a transverse temperature of 94(5) microK, a longitudinal temperature as low as 231(65) microK, and a tunable mean velocity between 5 and 20 m/s. Custom in-vacuum mirrors integrate the reflective geometry for the off-axis OM beams with a 0.8 mm output aperture, ensuring stable alignment while suppressing stray light and fluorescence leakage. Ultra-low light shift and decoherence are verified via continuous Raman-Ramsey interferometry, yielding a light shift of -0.51(4)Hz and a typical fringe contrast of 90.85(30)% at a Raman separation of 100 mm (interrogation time of 8.70 ms). This compact continuous cold-atom beam source constitutes a practical building block for atomic-beam clocks and interferometers, enabling reduced aliasing noise together with improved sensitivity and accuracy for field applications.
academic

Compact Continuous Cold Atomic Beam from a Single Cell with 3D Cooling and Ultra-low Light Shift

Basic Information

  • Paper ID: 2510.13126
  • Title: Compact Continuous Cold Atomic Beam from a Single Cell with 3D Cooling and Ultra-low Light Shift
  • Authors: Sheng-Zhe Wang, Qian-Lan Cai, Zhi-Xin Meng, Yi-Cheng Deng, Yan-Ying Feng
  • Classification: physics.atom-ph physics.app-ph
  • Publication Date: October 16, 2025
  • Paper Link: https://arxiv.org/abs/2510.13126

Abstract

This paper reports a compact single-cell continuous cold atomic beam source implementing three-dimensional (3D) cooling. By combining off-axis moving optical molasses (OM) with a two-dimensional magneto-optical trap (MOT), simultaneous 3D cooling is achieved within a 50 mm interaction region. The source provides continuous flux up to 4.9(5)×10⁹ atoms/second, with transverse temperature of 94(5) μK and longitudinal temperature as low as 231(65) μK, with mean velocity tunable between 5-20 m/s. A custom in-vacuum reflecting mirror combines the reflected geometry of the off-axis OM beam with a 0.8 mm output aperture, ensuring stable alignment while suppressing stray light and fluorescence leakage. Ultra-low light shift and decoherence are verified through continuous Raman-Ramsey interferometry, yielding a light shift of -0.51(4) Hz at a 100 mm Raman separation distance (8.70 ms interrogation time), with typical fringe contrast of 90.85(30)%.

Research Background and Motivation

Problem Definition

Continuous cold atomic beam sources have broad application prospects in atomic frequency standards, atomic interferometric inertial sensing, and quantum simulation. Existing technologies face the following core challenges:

  1. Longitudinal heating problem: Traditional single-cell MOT-based sources rely on push beams to extract atoms, which are heated rather than cooled in the extraction column, resulting in longitudinal temperatures reaching tens of millikelvin
  2. Light shift and decoherence: Push laser beams and near-resonant fluorescence leakage induce light shift and decoherence in the downstream interrogation region, limiting precision applications
  3. Compactness challenge: Multi-stage cooling methods, while providing superior longitudinal cooling, increase system complexity and are unsuitable for deployable applications

Research Motivation

The limitations of existing methods motivate the search for novel solutions:

  • Thermal atomic beam methods, while providing high flux, suffer from large mean velocity and lack longitudinal cooling
  • Traditional MOT methods achieve sub-Doppler transverse cooling but maintain longitudinal temperatures at tens of millikelvin
  • Multi-stage cooling increases system complexity, unsuitable for field deployment

Core Contributions

  1. Proposes novel off-axis moving optical molasses method: Achieves genuine 3D cooling in a single cell by combining off-axis moving OM with 2D MOT
  2. Eliminates longitudinal heating mechanism: Completely removes longitudinal heating caused by traditional push beams, reducing longitudinal temperature by nearly two orders of magnitude
  3. Achieves ultra-low light shift: Reduces light shift to -0.51(4) Hz through custom in-vacuum reflecting mirror and 0.8 mm aperture design
  4. Validates practical performance: Achieves high flux (4.9×10⁹ atoms/second) and low temperature (transverse 94 μK, longitudinal 231 μK) within compact 50 mm interaction region
  5. Provides tunable velocity: Enables 5-20 m/s adjustable mean velocity through symmetric frequency shift

Methodology Details

Fundamental Principles

Limitations of Traditional Methods

Traditional MOT-based single-cell sources rely on unidirectional push beams in the extraction column to drive atoms, but atoms are heated rather than cooled in this region, as shown in Figure 1(a).

Innovative Design

The proposed off-axis moving OM method eliminates push beams through the following mechanism:

  1. 2D MOT: Confines atoms in a cylindrical region and provides transverse cooling
  2. Off-axis moving OM: Cools atoms in the moving reference frame through symmetric frequency-shifted forward (FOM) and backward (BOM) OM beams at frequencies ±δOM

Mathematical Description

The mean velocity of atoms is given by:

v = λ/(cos θ) × δOM

where λ is the optical wavelength and θ is the angle of the OM beam relative to the extraction axis.

Theoretical Modeling

Scattering Force Model

Employs two-level Doppler cooling and trapping model, treating atoms as massive particles subject to random scattering forces from laser:

Rscatt,i = (Γ/2) × si/(1 + Σsi + (2δi/Γ)²)
Fscatt,i = ℏki × Rscatt,i

where Γ is the natural linewidth, si is the saturation parameter, and δi is the detuning.

Temperature Prediction

Numerical simulations show that reducing the extraction column diameter to zero can reduce longitudinal temperature by nearly two orders of magnitude, confirming that the extraction column is the primary heating source in traditional MOT configurations.

System Architecture

Optical System

  • 2D MOT: Two pairs of orthogonal circularly polarized laser beams, detuning ΔMOT = -4Γ
  • Off-axis OM: Two pairs of counter-propagating beams at 20° angle to output axis, lin⊥lin polarization configuration
  • Custom reflecting mirror: Polished aluminum surface in vacuum, ensuring stable alignment

Magnetic Field System

  • Cylindrical quadrupole magnetic field with gradients ~10 Gauss/cm in x and y directions
  • Magnetic field generated by four permanent magnets, fine-tunable through kinematic mounts

Experimental Setup

Experimental Apparatus

Uses ⁸⁷Rb atoms with integrated off-axis moving OM and 2D MOT in 50 mm interaction region:

  • Cooling length lc = 50 mm
  • OM interaction length lOM ≈ 50 mm
  • Total apparatus length ~170 mm
  • Output aperture da = 0.8 mm

Measurement Methods

Time-of-Flight (TOF) Measurement

  • Detection distances: 294 mm (primary) and 93 mm (confirmation)
  • State preparation laser at 40 mm downstream
  • Fluorescence detection using calibrated photomultiplier tube

Raman Spectroscopy Measurement

  • Doppler-sensitive stimulated Raman transition for transverse temperature measurement
  • Beam shaping produces 50 kHz transit time linewidth
  • Temperature resolution 0.7 μK

Raman-Ramsey Interferometry

  • Spatial domain implementation with separation distance L = 100 mm
  • Magnetic shielding with residual inhomogeneity ±300 nT
  • Microwave local oscillator locked to rubidium frequency standard

Experimental Results

Primary Performance Metrics

Temperature and Flux

  • Transverse temperature: 94(5) μK (theoretical prediction 62.8 μK)
  • Longitudinal temperature: Minimum 231(65) μK (typical 800±200 μK)
  • Atomic flux: Up to 4.9(5)×10⁹ atoms/second
  • Mean velocity: Tunable 5-20 m/s

Velocity Tuning Characteristics

Experiments verify linear relationship between velocity and frequency shift, theoretical slope 1.2 (m/s)/MHz:

  • Longer OM interaction length achieves better theoretical agreement
  • Achievable velocity limited by lOM

Light Shift and Decoherence Measurement

Raman-Ramsey Interferometry Results

  • Fringe contrast: 90.85(30)% (L=100 mm)
  • Light shift: -0.51(4) Hz
  • Decoherence rate: 6.95 s⁻¹ (experimental) vs 5.34 s⁻¹ (theoretical)

Decoherence Source Analysis

Total source-induced contrast loss 6.04(70)%, including:

  • MOT stray light: 4.43(30)%
  • BOM stray light: 0.33(20)%
  • Atomic fluorescence: 1.28(82)%
  • FOM contribution negligible

Ablation Experiments

Output Aperture Effect

The 0.8 mm aperture effectively isolates stray light and fluorescence while maintaining low transverse temperature (62.8 μK) and high flux (6.1×10⁹ atoms/second).

OM Parameter Optimization

  • Saturation parameter below 3 fails to reach equilibrium, resulting in higher longitudinal temperature
  • Beyond this point, temperature increases slowly, qualitatively consistent with Doppler theory

Development History of Continuous Cold Atomic Beams

Early Methods

  • Thermal atomic beam extraction: Phillips and Metcalf's laser slowing, Zhu et al.'s broadband cooling
  • 2D optical molasses: For transverse cooling, but lacking longitudinal cooling

MOT-Based Methods

  • LVIS and 3D MOT: Lu et al.'s low-velocity intense source
  • 2D MOT: Dieckmann et al.'s pyramid MOT
  • 2D+ MOT: Park et al.'s dual-color push laser

Multi-Stage Cooling

Kwolek and Black's three-dimensional cooling atomic beam source, though with higher system complexity.

Advantages of This Work

Compared to existing single-cell cold atomic beam sources, this work achieves:

  • Longitudinal temperature reduction by 1-2 orders of magnitude
  • Elimination of push beam light shift
  • Maintenance of compact single-cell design

Conclusions and Discussion

Main Conclusions

  1. Technical breakthrough: First genuine 3D cooling in a single cell, achieving 231 μK longitudinal temperature
  2. Ultra-low light shift: -0.51 Hz light shift has negligible impact on precision applications
  3. Practical performance: High flux, tunable velocity, and compact design suitable for field deployment
  4. Theoretical verification: Experimental results show good agreement with theoretical models

Limitations

  1. Velocity limitation: Maximum achievable velocity constrained by OM interaction length
  2. Magnetic field effects: Residual magnetic field in 2D MOT suppresses polarization gradient cooling
  3. Flux-temperature tradeoff: Reducing output aperture lowers temperature but also reduces flux

Future Directions

  1. Higher velocities: Achieve velocities up to 50 m/s using dual-color forward OM beams
  2. Further cooling: Raman sideband cooling, dipole trapping, or custom magnetic field distribution
  3. Polarization gradient cooling: Design specialized magnetic field distribution to enable polarization gradient regions

In-Depth Evaluation

Strengths

  1. Strong innovation: Novel off-axis moving OM concept effectively addresses fundamental problems of traditional methods
  2. Solid theory: Complete theoretical modeling and numerical simulations support experimental design
  3. Comprehensive experiments: Full performance characterization including temperature, flux, light shift, and decoherence
  4. High practical value: Compact design suitable for field applications in atomic clocks and interferometers
  5. Advanced technology: Engineering innovations such as custom in-vacuum reflecting mirror ensure system stability

Weaknesses

  1. Velocity range limitation: 5-20 m/s velocity range may limit certain applications
  2. Complexity: While simpler than multi-stage cooling, still requires precise optical and magnetic field control
  3. Atomic species limitation: Currently verified only on ⁸⁷Rb; applicability to other atomic species unknown

Impact

  1. Academic contribution: Provides new design paradigm for cold atomic beam source field
  2. Application prospects: Direct applicability to atomic clocks, inertial sensors, and other precision instruments
  3. Technology promotion: Compact design facilitates industrialization of cold atom technology

Applicable Scenarios

  • Portable atomic clocks and frequency standards
  • Atomic interferometric inertial sensors
  • Quantum precision measurement devices
  • Atomic lithography and quantum simulation experiments

References

The paper cites 49 important references covering:

  • Fundamental laser cooling and trapping theory
  • Development of various cold atomic beam source technologies
  • Atomic interferometer and atomic clock applications
  • Light shift and decoherence mechanism research

This work represents significant progress in cold atomic beam source technology, solving long-standing technical challenges through clever physical design, paving the way for practical implementation of precision atomic physics instruments. Its compactness and excellent performance make it an ideal component for next-generation atomic clocks and interferometers.