2025-11-25T02:19:17.918625

Molecularly imprinted nanopores for multiplexed sensing, release, and in-edge computing

Douaki, Weng, Dante et al.
In nanopore technology, the development of multiplexed detection and release platforms with high spatial and temporal resolution remains a significant challenge due to the difficulty in distinguishing signals originating from different nanopores in a single chip. In this work, we present a solid-state nanopore system functionalized with molecularly imprinted polymers (MIPs) for the selective detection and controlled release of neurotransmitters. We designed a nanopore array where each nanopore is functionalized with a specific MIP able to recognize specific neurotransmitters (dopamine, gamma-aminobutyric acid, and histamine, respectively). The platform demonstrated high performance in terms of sensitivity, selectivity, recovery, and stability. Multiplexed detection with high spatiotemporal resolution of the order of 100 ms/ 3 μm was achieved by specifically depositing MIPs and conductive hydrogels on different nanopores prepared on a single solid-state membrane. The employment of micro-chambers for each nanopore prevented signal cross-talk, thereby enabling simultaneous detection and release of multiple neurotransmitters. Moreover, we demonstrated computing with different logic gates and in-edge computing. This nanopore platform represents a radically novel approach towards hybrid solid-state nanopores able to perform real-time label-free multiplex detection, controlled biomolecule release, and ionic logic computing, addressing key challenges in neurochemical sensing and bio-computation.
academic

Molecularly Imprinted Nanopores for Multiplexed Sensing, Release, and In-Edge Computing

Basic Information

  • Paper ID: 2510.13490
  • Title: Molecularly imprinted nanopores for multiplexed sensing, release, and in-edge computing
  • Authors: Ali Douaki, Shukun Weng, Silvia Dante, Nako Nakatsuka, Makusu Tsutsui, Roman Krahne, Denis Garoli
  • Classification: physics.app-ph (Applied Physics)
  • Institutions: Italian Institute of Technology, École Polytechnique Fédérale de Lausanne, Osaka University, University of Modena
  • Paper Link: https://arxiv.org/abs/2510.13490

Abstract

This study presents a solid-state nanopore system functionalized with molecularly imprinted polymers (MIPs) for selective detection and controlled release of neurotransmitters. The research team designed a nanopore array where each nanopore is functionalized with specific MIPs capable of recognizing particular neurotransmitters (dopamine, γ-aminobutyric acid, and histamine). The platform demonstrates excellent performance in sensitivity, selectivity, recovery rate, and stability, achieving high spatiotemporal resolution multiplexed detection of approximately 100 milliseconds/3 micrometers, and demonstrates logic gate operations and edge computing capabilities.

Research Background and Motivation

Problem Definition

In nanopore technology, developing multiplexed detection and release platforms with high spatiotemporal resolution remains a significant challenge, with the primary difficulty being the inability to distinguish signals from different nanopores on a single chip.

Significance

  1. Neuroscience Requirements: Neurotransmitters such as dopamine, GABA, and histamine play critical roles in brain function, and their dysregulation is associated with diseases including depression, Parkinson's disease, and schizophrenia
  2. Biological Process Monitoring: Many biological processes occur in highly confined spaces with timescales of milliseconds to tens of milliseconds, requiring detection platforms with high spatiotemporal resolution
  3. Real-time Multiplexed Detection: Simultaneous monitoring of multiple neurotransmitter levels is essential for understanding complex neural processes

Limitations of Existing Methods

  1. Traditional Detection Methods: Conventional detection based on electrochemical and optical methods suffer from inadequate spatiotemporal resolution, operational complexity, and selectivity
  2. Signal Crosstalk: Difficulty in distinguishing signals from different nanopores in multiplexed systems affects measurement and control precision
  3. Lack of Integration: Existing systems lack the ability to integrate sensing, computing, and release functions on a single platform

Core Contributions

  1. First MIP-Nanopore Integration: Development of the first multiplexed sensing platform integrating molecularly imprinted polymers with solid-state nanopores
  2. Resolution of Signal Crosstalk: Achievement of independent current measurements through conductive hydrogel microchamber technology, preventing signal interference
  3. Multifunctional Integrated Platform: Implementation of triple-function integration of sensing, controlled release, and ionic logic computation
  4. High-Performance Detection: Achievement of picomolar-level detection limits (dopamine 2.82 pM, GABA 1.99 pM, histamine 2 nM)
  5. Edge Computing Capability: First demonstration of logic gates (NOT, NOR, NAND) and edge computing based on neurotransmitters

Methodology Details

Task Definition

Construction of an integrated nanopore platform capable of simultaneous real-time detection of multiple neurotransmitters, controlled release, and logic computation.

Core Technical Architecture

1. MIP-Nanopore Sensor Preparation

  • Nanopore Fabrication: Preparation of nanopores with diameter 40±10 nm on Si₃N₄ membranes using focused ion beam (FIB)
  • Surface Functionalization: APTES coating treatment via atomic layer deposition
  • MIP Synthesis: In-situ polymerization using methacrylic acid (MAA), acrylamide (ACM), and crosslinker MBAA in a 1:2:2:10 molar ratio

2. Multiplexed Detection System Design

  • Spatial Separation: Preparation of three nanopores functionalized with different MIPs on a single Si₃N₄ membrane
  • Conductive Hydrogel Microchambers: Use of polyvinyl alcohol-sodium alginate composite hydrogel as independent ion transport channels
  • Anti-Crosstalk Mechanism: Design with shared cis-chamber and independent trans-chambers to prevent signal interference

3. Operating Principle

  • Detection Principle: Target molecule binding to MIP causes partial nanopore blockade, reducing ionic current
  • Release Mechanism: Controlled molecular release through electric field-assisted electrostatic desorption
  • Logic Operations: Implementation of logic gate functions based on binary inputs of neurotransmitter presence/absence

Technical Innovations

  1. First Combination of Molecular Imprinting and Nanopores: Utilization of MIP's high selectivity to address nanopore sensor specificity issues
  2. Conductive Hydrogel Microchamber Technology: Innovative solution to signal crosstalk problems in multiplexed systems
  3. Electric Field-Assisted Release Mechanism: Rapid and controlled molecular release through local potential drop (~0.1V)
  4. Biological Logic Computation: First implementation of ionic logic operations based on neurotransmitters

Experimental Setup

Materials and Reagents

  • Buffer Solution: 1× PBS (137 mM NaCl, 2.7 mM KCl, 10 mM Na₂HPO₄, 1.8 mM KH₂PO₄, pH 7.4)
  • Target Molecules: Dopamine, GABA, histamine
  • Complex Media: Neurobasal medium

Characterization Methods

  • Morphological Characterization: SEM, AFM
  • Spectroscopic Analysis: UV-Vis spectrophotometry
  • Kinetic Analysis: Quartz crystal microbalance with dissipation (QCM-D)
  • Electrical Measurements: Ionic conductance measurements

Performance Evaluation Metrics

  • Sensitivity: Limit of detection (LOD) and limit of quantification (LOQ)
  • Selectivity: Cross-reactivity with structurally similar compounds
  • Stability: Long-term storage stability and reusability
  • Spatiotemporal Resolution: Response time and spatial resolution

Experimental Results

Single Sensor Performance

Dopamine Sensor

  • Detection Range: 1 pM - 100 μM
  • Detection Limit: 2.82 pM (LOD), 23.20 pM (LOQ)
  • Selectivity: Cross-reactivity with norepinephrine and serotonin of 5.75±0.56% and 3.75±0.2%, respectively
  • Stability: Maintains >95% initial sensitivity after 6 cycles, 97.2±7.0% response within 9 days

GABA Sensor

  • Detection Range: 0.1 nM - 100 mM
  • Detection Limit: 1.99 pM
  • Linearity: R² = 0.96
  • Stability: Maintains 92% initial sensitivity after 15 cycles

Histamine Sensor

  • Detection Range: 1 nM - 100 mM
  • Detection Limit: 2 nM
  • Linearity: R² = 0.97
  • Stability: Maintains 90% initial sensitivity after 15 cycles, stable performance within 30 days

Multiplexed Detection Performance

  • Spatiotemporal Resolution: ~100 ms / 3 μm
  • Selective Detection: Each nanopore produces significant response only to its specific target (~25-30% current reduction)
  • Anti-Crosstalk: Successful achievement of independent signal measurement

Controlled Release Performance

  • Release Efficiency: Approximately 80% of drug-loaded molecules released after 5 pulses
  • Release Mechanism: Electric field-assisted electrostatic desorption with local potential drop ~0.1V
  • Reversibility: Six detection-release cycles verify platform's reversible operation capability

Logic Computation Function

Successful implementation of NOT, NOR, and NAND logic gate operations, providing new possibilities for biological computing and neuromorphic systems.

Nanopore Sensing Technology

Nanopore technology has emerged as one of the most promising techniques due to its high sensitivity, label-free detection, and real-time monitoring capabilities, though multiplexed label-free detection remains challenging.

Molecular Imprinting Technology

MIPs have demonstrated tremendous potential in enhancing selectivity in electrochemical sensors and field-effect transistors, but their combination with nanopores has been largely unexplored.

In-Memory Computing and Edge Computing

Successfully implemented on multiple platforms including resistive devices, photonic systems, and crossbar arrays, though complete experimental integration of sensing and computing in single storage units remains largely unexplored.

Conclusions and Discussion

Main Conclusions

  1. Successful development of the first MIP-functionalized nanopore multiplexed sensing platform
  2. Achievement of picomolar-level high-sensitivity detection
  3. Resolution of signal crosstalk through conductive hydrogel technology
  4. Demonstration of triple-function integration of sensing, release, and logic computation
  5. Provision of new technological pathways for neurochemical monitoring and biological computing

Limitations

  1. Complex Media Effects: Response in neurobasal medium slightly lower than in PBS buffer
  2. Temperature Sensitivity: Requires operation under specific temperature conditions
  3. Long-term Stability: Although performance is good, longer-term stability verification remains necessary
  4. Fabrication Complexity: Requires precision micromachining and chemical synthesis techniques

Future Directions

  1. Expansion of Target Molecules: Development of MIP sensors for additional neurotransmitter types
  2. Increased Integration: Increase the number of nanopores on a single chip
  3. In Vivo Applications: Development of miniaturized systems suitable for live detection
  4. Intelligent Algorithms: Integration of machine learning algorithms to improve detection accuracy and predictive capability

In-Depth Evaluation

Strengths

Technical Innovation

  1. Pioneering Integration: First combination of MIP technology with nanopore sensing, opening new research directions
  2. Engineering Solutions: Conductive hydrogel microchamber technology elegantly resolves signal crosstalk in multiplexed systems
  3. Multifunctional Integration: Integration of sensing, release, and computation on a single platform with significant technical value

Experimental Sufficiency

  1. Comprehensive Characterization: Complete experimental design from single sensors to multiplexed systems, from material characterization to functional verification
  2. Excellent Performance: Detection limits reaching picomolar levels, meeting physiologically relevant concentration detection requirements
  3. Mechanistic Elucidation: In-depth investigation of release mechanisms through QCM-D and temperature experiments

Application Prospects

  1. Neuroscience Applications: Provision of new tools for real-time neurotransmitter monitoring
  2. Biological Computing: Opening new frontiers in logic computation based on biological molecules
  3. Intelligent Drug Release: Provision of new technological platforms for precision medicine

Shortcomings

Methodological Limitations

  1. Fabrication Complexity: Requires multi-step precision processing, potentially affecting mass production and standardization
  2. Environmental Sensitivity: Relatively sensitive to environmental conditions such as pH and temperature
  3. Cross-reactivity: Although selectivity is good, some degree of cross-reactivity remains

Experimental Setup Defects

  1. Biological Relevance: Testing primarily conducted in buffer solutions, with gaps compared to real biological environments
  2. Long-term Stability: Although 9-30 day testing was performed, longer-term verification may be necessary for practical applications
  3. Throughput Limitations: Currently demonstrates integration of only 3 nanopores; scalability requires further verification

Impact Assessment

Academic Contribution

  1. Interdisciplinary Fusion: Organic integration of materials science, nanotechnology, biosensing, and computational science
  2. Methodological Innovation: Provision of new functionalization strategies for nanopore sensing technology
  3. Theoretical Advancement: In-depth theoretical analysis of electric field-assisted molecular desorption mechanisms

Practical Value

  1. Medical Diagnostics: Application in early diagnosis and monitoring of neurological disorders
  2. Drug Development: Provision of new tools for neurologically active drug screening and evaluation
  3. Bioengineering: Provision of hardware foundation for synthetic biology and biological computing

Reproducibility

The paper provides detailed material preparation, experimental methods, and data analysis procedures, demonstrating good reproducibility.

Applicable Scenarios

  1. Neuroscience Research: Investigation of neurotransmitter dynamics
  2. Clinical Diagnostics: Detection of biomarkers for neurological disorders
  3. Drug Screening: Evaluation of neurologically active drug efficacy
  4. Biological Computing: Construction of molecular logic circuits
  5. Smart Materials: Responsive drug release systems

References

The paper cites 80 relevant references covering important works in nanopore technology, molecular imprinting, neuroscience, biosensing, and computational science, providing a solid theoretical foundation for the research.


Overall Assessment: This is an innovative interdisciplinary research paper of significant importance that successfully combines molecular imprinting technology with nanopore sensing, achieving a multifunctional integrated biosensing platform. The paper demonstrates excellence in technical innovation, experimental verification, and application prospects, making important contributions to the development of nanoscale biosensing and biological computing. Despite some technical challenges and application limitations, its pioneering work establishes an important foundation for future research and applications.