Coherent elastic neutrino-nucleus scattering (CEvNS) provides a powerful framework for testing the Standard Model (SM) and searching for new physics at low energies. In this work, we examine the prospects for argon-based CEvNS experiments at stopped-pion sources to perform precision measurements of weak interactions and probe non-standard neutrino properties. Our study focused on the CENNS-10 and CENNS-750 detectors at the Spallation Neutron Source at Oak Ridge National Laboratory, the Coherent Captain Mills (CCM) detector at Los Alamos National Laboratory, and the proposed PIP2-BD detector at Fermilabs Facility for Dark Matter Discovery (F2D2). Using realistic neutrino fluxes and detector configurations corresponding to these facilities, we evaluate event rates and sensitivities to a range of observables. Within the SM, argon-based CEvNS detectors enable precision tests of electroweak parameters, including the weak mixing angle, at momentum transfers well below the electroweak scale. We also investigate the sensitivity of these experiments to neutrino electromagnetic properties, such as the magnetic moment and effective charge radius, as well as to possible non-standard neutrino interactions with quarks. Together, these studies highlight the potential of argon-based CEvNS experiments as a clean and versatile platform for precision exploration of non-standard neutrino properties.
- ID del Artículo: 2510.14015
- Título: Prospects for Exploring Non-Standard Neutrino Properties with Argon-Based CEvNS Experiments
- Autores: S. Carey (Wayne State University), V. Pandey (Fermi National Accelerator Laboratory)
- Clasificación: hep-ph (Física Teórica), hep-ex (Física Experimental)
- Fecha de Publicación: 15 de octubre de 2025
- Enlace del Artículo: https://arxiv.org/abs/2510.14015
Este artículo investiga las perspectivas de explorar propiedades no estándar de neutrinos mediante experimentos de dispersión elástica coherente neutrino-núcleo (CEvNS) basados en argón en fuentes de piones detenidos. La investigación se enfoca en los detectores CENNS-10 y CENNS-750 de la Fuente de Neutrones por Espalación del Laboratorio Nacional de Oak Ridge, el detector de Coherent Captain Mills (CCM) del Laboratorio Nacional de Los Álamos, y el detector PIP2-BD propuesto por la Instalación de Descubrimiento de Materia Oscura (F2D2) del Fermilab. Mediante el uso de flujos de neutrinos realistas y configuraciones de detectores, se evalúan las tasas de eventos y la sensibilidad a múltiples observables. Dentro del marco del Modelo Estándar, los detectores CEvNS basados en argón pueden realizar pruebas de precisión de parámetros electrodebles (incluyendo el ángulo de mezcla débil) a transferencias de momento muy por debajo de la escala electrodébil, mientras que se investiga la sensibilidad de estos experimentos a propiedades electromagnéticas de neutrinos (como momento magnético y radio de carga efectivo) así como posibles interacciones neutrino-quark no estándar.
- Importancia de CEvNS: La dispersión elástica coherente neutrino-núcleo es una predicción directa del Modelo Estándar de mediados de los años 1970, pero su detección ha sido difícil debido a la necesidad de medir retrocesos nucleares extremadamente pequeños (típicamente en el rango de decenas de keV), hasta que la colaboración COHERENT observó por primera vez este fenómeno en 2017.
- Significado Físico: CEvNS proporciona oportunidades únicas para probar parámetros del Modelo Estándar y buscar señales de nueva física más allá del Modelo Estándar, incluyendo:
- Medición de precisión del ángulo de mezcla débil a baja transferencia de momento
- Detección de propiedades electromagnéticas de neutrinos
- Restricciones sobre interacciones de neutrinos no estándar (NSI)
- Ventajas Técnicas: Las fuentes de neutrinos de piones detenidos son particularmente adecuadas para investigación de CEvNS, ya que producen flujos de neutrinos en el rango de energía de decenas de MeV, donde la sección transversal de CEvNS es relativamente grande y la energía de retroceso está dentro del rango de detección de detectores modernos de bajo umbral.
El argón líquido como material objetivo del detector posee ventajas únicas:
- Abundante y escalable, permitiendo la construcción de detectores de escala multitoneláda
- Las propiedades nucleares proporcionan información complementaria a núcleos pesados
- La tecnología de detectores de argón desarrollada en experimentos de oscilación de neutrinos puede aplicarse a CEvNS
- Análisis Teórico Sistemático: Proporciona un marco teórico completo para experimentos de CEvNS basados en argón, incluyendo análisis del impacto de diferentes modelos de factores de forma nuclear en cálculos de sección transversal
- Evaluación de Múltiples Plataformas Experimentales: Realiza análisis de sensibilidad unificado para cuatro importantes experimentos de CEvNS basados en argón (CENNS-10/750, CCM, PIP2-BD)
- Mediciones Electrodebles de Precisión: Evalúa la precisión de medición de estos experimentos para el ángulo de mezcla débil sin²θW, demostrando precisión comparable o superior a las mediciones de baja energía existentes
- Capacidad de Detección de Nueva Física: Cuantifica la sensibilidad a propiedades electromagnéticas de neutrinos (momento magnético, radio de carga) y parámetros de interacciones no estándar
- Impacto de Errores Sistemáticos: Investiga el impacto de diferentes niveles de error sistemático (5% y 10%) en diversas mediciones
Para la dispersión de un neutrino incidente con energía Eν sobre un núcleo de argón en reposo, la sección transversal diferencial en el Modelo Estándar es:
[dTdσ(Eν)]SM=4πGF2QW2MA(1−EνT−2Eν2MAT)FWeak2(Q2)
Donde:
- T es la energía de retroceso nuclear
- GF es la constante de acoplamiento de Fermi
- QW es la carga nuclear débil: QW=[(1−4sin2θW)Z−N]
- MA es la masa del núcleo de argón
- FWeak es el factor de forma nuclear débil
El artículo compara seis modelos diferentes de factores de forma nuclear:
- Factor de forma de Helm (referencia): FHelm(Q2)=QR3j1(QR)e−Q2s2/2
- Modelo de Klein-Nystrand
- Modelo de Hartree-Fock de Van Dessel et al.
- Modelo NNLO de Payne et al.
- Modelo de campo medio relativista de Yang et al.
- Modelo EFT-SM de Hoferichter et al.
Las diferencias entre modelos introducen un error sistemático menor al 3%.
La fórmula de tasa de eventos diferencial es:
dTdN=AmNfν/pmT∑i=νμ,νe,νˉμ∫Eνminmμ/2dEνdEνdϕi[dTdσ(Eν)]SM
El número de eventos reconstruidos después de considerar la eficiencia del detector y la resolución energética es:
Ni=∫Trec,i−ΔTrec/2Trec,i+ΔTrec/2dTrecϵ(Trec)×∫Tmin∞dTdTdNR(Trec,TI;σI)
| Experimento | Masa Objetivo (kg) | Distancia (m) | Intensidad de Haz de Protones (POT/s) | Ubicación |
|---|
| CENNS-10 | 24 | 27.5 | 1.0×10¹⁶ | ORNL |
| CENNS-750 | 610 | 27.5 | 7.6×10¹⁵ | ORNL |
| CCM | 10,000 | 20.0 | 5.6×10¹⁴ | LANL |
| PIP2-BD | 100,000 | 20.0 | 2.75×10¹⁶ | FNAL |
- Caso Base: Error sistemático combinado del 10% (incluyendo normalización de flujo de neutrinos, factor de desexcitación, eficiencia del detector, factor de forma nuclear)
- Caso Optimizado: Error sistemático del 5% (logrado mediante monitor de flujo dedicado)
Análisis estadístico usando χ²:
χ2({λ})=minη{NSM[NSM−NSignal({λ})(1+η)]2+(σηη)2}
| Experimento (Error Sistemático) | Rango sin²θW 90% C.L. |
|---|
| PIP2-BD (5%) | 0.2272, 0.2515 |
| PIP2-BD (10%) | 0.2171, 0.2662 |
| CENNS-750 (5%) | 0.2271, 0.2516 |
| CENNS-750 (10%) | 0.2170, 0.2663 |
PIP2-BD con error sistemático del 5% puede lograr precisión comparable o superior a las mediciones de baja energía existentes.
| Experimento (Error Sistemático) | Límite Superior μν (×10⁻¹⁰μB, 90% C.L.) |
|---|
| PIP2-BD (5%) | 9.93 |
| PIP2-BD (10%) | 14.7 |
| CENNS-750 (5%) | 10.6 |
| CENNS-750 (10%) | 15.6 |
Estos resultados mejoran las restricciones existentes de CEvNS en casi un orden de magnitud.
Rango de restricción al 90% C.L. (×10⁻³²cm²):
- PIP2-BD (5%): -12.78,-12.28 ∪ -0.24,0.26
- PIP2-BD (10%): -13.10,-12.06 ∪ -0.44,0.58
Para parámetros NSI diagonales de sabor εᵘⱽₑₑ y εᵈⱽₑₑ, PIP2-BD con error sistemático del 5% puede lograr:
- εᵘⱽₑₑ: -0.024,0.022 ∪ 0.342,0.388
- εᵈⱽₑₑ: -0.022,0.020 ∪ 0.320,0.364
- Colaboración COHERENT: Primera observación de CEvNS en 2017, seguida de mediciones con múltiples tecnologías de detectores
- Otros Experimentos: Los experimentos Dresden-II y NUCLEUS proporcionan mediciones complementarias
- Desarrollo Teórico: Cálculos de precisión de factores de forma nucleares, marcos teóricos para efectos de nueva física
- Experimentos de paridad atómica (APV)
- Medición de Qweak en dispersión electrón-protón
- Medición de dispersión neutrino-electrón en experimentos de detección directa de materia oscura
- Mediciones Electrodebles de Precisión: Los detectores de argón de gran masa (particularmente PIP2-BD y CENNS-750) pueden realizar mediciones de precisión del ángulo de mezcla débil con precisión comparable o superior a las mediciones de baja energía existentes
- Detección de Propiedades Electromagnéticas: Estos experimentos tienen sensibilidad al momento magnético de neutrinos que mejora las restricciones existentes de CEvNS en casi un orden de magnitud, acercándose a la región de sensibilidad teóricamente esperada
- Restricciones NSI: Proporcionan restricciones competitivas sobre parámetros de interacciones no estándar, con sensibilidad significativamente mejorada en detectores de gran masa
- Importancia del Error Sistemático: La reducción del error sistemático del 10% al 5% puede mejorar significativamente la precisión de todas las mediciones
- Suposiciones de Fondo: El análisis asume supresión ideal de fondo, el fondo real en experimentos podría afectar la sensibilidad
- Error Sistemático: Aunque se consideran las principales fuentes de error sistemático, pueden existir otros efectos sistemáticos no considerados
- Incertidumbre Teórica: Aunque la incertidumbre teórica del factor de forma nuclear es pequeña, aún existe
- Mejoras Experimentales: Desarrollo de tecnología de detectores con umbral más bajo, mejora de la resolución energética
- Monitoreo de Flujo: Implementación de monitores de flujo de neutrinos dedicados para reducir errores sistemáticos
- Mediciones de Múltiples Núcleos Objetivo: Combinación de mediciones con diferentes núcleos objetivo para romper degeneraciones de parámetros
- Integralidad: Analiza sistemáticamente cuatro importantes plataformas experimentales de CEvNS basadas en argón, proporcionando un marco de comparación unificado
- Rigor Teórico: Considera detalladamente la incertidumbre de factores de forma nucleares, utilizando los resultados de cálculos teóricos más recientes
- Valor Práctico: Proporciona referencias importantes para el diseño experimental y el establecimiento de objetivos físicos
- Innovación Metodológica: El marco de análisis estadístico unificado es aplicable a diferentes tipos de búsquedas de nueva física
- Tratamiento de Fondo: El tratamiento del fondo experimental es relativamente simplificado, posiblemente sobreestimando la sensibilidad real
- Correlaciones: No considera suficientemente las correlaciones entre diferentes parámetros y degeneraciones
- Detalles Experimentales: La descripción de la respuesta específica del detector y algoritmos de reconstrucción es limitada
- Contribución Académica: Proporciona una base teórica importante para la física de CEvNS y orientación experimental
- Orientación Experimental: Proporciona motivación física para el diseño de detectores de argón de gran escala futuros
- Impacto en Políticas: Puede influir en decisiones de financiamiento de proyectos experimentales relacionados
- Diseño Experimental: Aplicable al diseño y optimización de experimentos de CEvNS
- Análisis Físico: Proporciona marco teórico para la interpretación física de datos de CEvNS
- Búsqueda de Nueva Física: Proporciona expectativas de sensibilidad para búsquedas de nueva física más allá del Modelo Estándar
El artículo cita 96 referencias relacionadas, que abarcan teoría de CEvNS, progreso experimental, cálculos de física nuclear, modelos de nueva física y otros aspectos, reflejando el progreso de investigación más reciente en este campo. Las referencias importantes incluyen el trabajo pionero de la colaboración COHERENT, cálculos teóricos de varios factores de forma nucleares, y marcos teóricos para efectos de nueva física.